![Omron 3G3AX-PG Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/omron/3g3ax-pg/3g3ax-pg_user-manual_742466031.webp)
3-4
3-1 Related Parameters
3
Opera
tion
Parameter
No.
Function name
Data range
Default setting
Changes dur-
ing operation
Unit
P001
Operation
selection at
option 1 error
00: Trip
01: Continues operation
00
×
−
P002
Operation
selection at
option 2 error
00: Trip
01: Continues operation
00
×
−
P011
Encoder pulses
128. to 9999.
1000 to 6500 (10000 to 65000)
1024.
×
Pulse
P012
V2 control mode
selection
00: ASR (speed control mode)
01: APR (pulse train position control
mode)
02: APR2 (absolute position control
mode)
03: HAPR (high-resolution absolute
position control mode)
00
×
−
P013
Pulse train mode
selection
00: Mode 0
01: Mode 1
02: Mode 2
00
×
−
P014
Orientation stop
position
0. to 4095.
0.
×
−
P015
Orientation speed
setting
Starting frequency to Max. frequency
(Upper limit 120.0)
5.00
×
Hz
P016
Orientation direction
setting
00: Forward side
01: Reverse side
00
×
−
P017
Position ready
range setting
0. to 9999.
1000 (10000)
5.
×
Pulse
P018
Position ready
delay time setting
0.00 to 9.99
0.00
×
s
P019
Electronic gear
setting position
selection
00: Position feedback side (FB)
01: Position command side (REF)
00
×
−
P020
Electronic gear
ratio numerator
0. to 9999.
1.
×
−
P021
Electronic gear
ratio denominator
0. to 9999.
1.
×
−
P022
Position control
feed forward gain
0.00 to 99.99
100.0 to 655.3
0.00
×
−
P023
Position loop gain
0.00 to 99.99
100.0
0.50
×
rad/s
P024
Position bias
amount
−
204 (
−
2048.) /
−
999. to 2048.
0.
{
−
Содержание 3G3AX-PG
Страница 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Страница 2: ......
Страница 14: ...12 Contents ...
Страница 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Страница 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Страница 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Страница 67: ......