4-1
4-1 V2 Control Mode Selection
4
Functions
4Functions
4-1 V2 Control Mode Selection
Select a control method in V2 control mode selection P012.
When “00” (ASR) is selected in P012, speed control mode is enabled. Select a frequency reference
in frequency reference selection A001.
When “01” (APR) is selected in P012, the Inverter enables position control by generating frequency
reference based on the position command pulse input from the pulse train position command input
terminal, and on the position feedback detected by the encoder.
Select any of the three pulse train position command input modes in pulse train mode selection
P013.
To perform pulse train position control, allocate “48” (STAT) to any of the multi-function input termi-
nals. While the STAT terminal is tuned on, pulse train position command input is accepted.
Position deviation can be cleared through external input. Allocate “47” (PCLR) to any of the multi-
function input terminals. Turning ON/OFF the PCLR terminal can clear position deviation data.
Allocating “22” (DSE) to any of the multi-function output terminals enables excessive speed devia-
tion signal output.
Set a deviation level in speed deviation error detection level P027. When the deviation between real
frequency and reference frequency exceeds the P027 set value, the DSE signal turns on.
When “02” (APR2) or “03” (HAPR) is selected in P012, the Inverter performs absolute position con-
trol with reference to the absolute position from its origin.
Parameter No.
Function name
Data
Default
setting
Unit
P012
V2 control mode selection
00: ASR (speed control mode)
01: APR (pulse train position control mode)
02: APR2 (absolute position control mode)
03: HAPR (high-resolution absolute position
control mode)
00
−
P011
Encoder pulses
128. to 9999./1000 to 6553
(10000 to 65535):
Number of encoder pulses
1024.
Pulse
P023
Position loop gain
0.00 to 99.99/100.0: Position loop gain
0.50
rad/s
P027
Speed deviation error
detection level
0.00 to 99.99/100.0 to 120.0:
DSE signal output level
7.50
Hz
H004
Motor pole number
selection
2/4/6/8/10: Select a motor pole number.
4
Pole
C001 to C008
Multi-function inputs 1 to 8
selection
47: PCLR (position deviation clear)
48: STAT (pulse train position command in-
put permission)
−
−
C021 to C025
Multi-function output ter-
minals P1 to P5 selection
22: DSE (excessive speed deviation)
−
−
C026
Relay output (MA, MB)
function selection
05
Related functions
A001, P013
Содержание 3G3AX-PG
Страница 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Страница 2: ......
Страница 14: ...12 Contents ...
Страница 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Страница 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Страница 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Страница 67: ......