Abnormal Performance
In-Cab Scanner Diagnostic Procedure
27-2
80-JB566-1 Rev. G
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Abnormal Performance
Note
Only scanners ordered through and obtained by BCS Solutions are supported by Omnitracs.
These scanners are specifically configured for Omnitracs in-cab products.
https://omnitracs.bcssolutions.com/q/mcpscn/default.aspx
If the scanner is not detected by the application or does not scan a document and you have
followed the instructions in
Chapter 8: In-Cab Scanner Installation
and, if necessary, the
Installation Procedure
that follows, there is a problem.
A problem is most likely caused by one or more of the following.
Software and/or OS
Verify software version CA0917R is present with Windows CE operating system LT0038 and
higher.
Loose USB Cable Connection
If the scanner is not detected, reseat the cable at both ends (scanner and MAS).
Scanner or Scanner Cable
If the scanner is detected but will not scan, run the calibration process and then try scanning
a document again.
If it is still not working, and if possible, connect a known-good scanner and scanner cable to
the MAS and attempt to scan and send a document.
If you still cannot scan and send a document, reset the MAS and try again.
Содержание MCP50
Страница 1: ...MCP50 Installation and Troubleshooting Guide 80 JB566 1 Rev G October 2015...
Страница 48: ...Troubleshooting Contents 80 JB566 1 Rev G MAY CONTAIN U S AND INTERNATIONAL EXPORT CONTROLLED INFORMATION...
Страница 92: ...Appendix Contents 80 JB566 1 Rev G MAY CONTAIN U S AND INTERNATIONAL EXPORT CONTROLLED INFORMATION...
Страница 110: ...Standard RMA Procedure D 2 80 JB566 1 Rev G MAY CONTAIN U S AND INTERNATIONAL EXPORT CONTROLLED INFORMATION...
Страница 124: ...Installation Form H 2 80 JB566 1 Rev G MAY CONTAIN U S AND INTERNATIONAL EXPORT CONTROLLED INFORMATION...