Data herein has been verified and validated. It is believed adequate for the intended use of the 
instrument. If the instrument or procedures are used for purposes over and above the capabilities 
specified herein, confirmation of the validity and suitability should be obtained; otherwise Omni 
International does not guarantee results and assumes no obligation or liability. This publication is 
not a license to operate under, or a recommendation to infringe upon, any process patents. 

This product is warranted to be free from defects in material and workmanship for a period of TWO 
YEARS from the date of delivery. Omni International will repair or replace and return free of charge 
any part which is returned to its factory within said period, transportation prepaid by user, and 
which is found upon inspection to have been defective in materials or workmanship. This warranty 
does not include normal wear from use; it does not apply to any instrument or parts which have 
been altered by anyone other than an employee of Omni International nor to any instrument which 
has been damaged through accident, negligence, failure to follow operating instructions, the use 
of electric currents or circuits other than those specified on the plate affixed to the instrument, 
misuse, or abuse. Omni International reserves the right to change, alter, modify, or improve any of its 
instruments without any obligation whatever to make corresponding changes to any instrument 
previously sold or shipped.

THE FORGOING OBLIGATION IS IN LIEU OF ALL OBLIGATIONS AND LIABILITIES INCLUDING 
NEGLIGENCE AND ALL WARRANTIES OF MERCHANTABILITY OR OTHERWISE, EXPRESSED OR IMPLIED 
IN FACT OR BY LAW, AND STATE OUR ENTIRE AND EXCLUSIVE LIABILITY AND BUYERS EXCLUSIVE 
REMEDY FOR ANY CLAIM OF DAMAGES IN CONNECTION WITH THE SALE OR FURNISHING OF 
GOODS OR PARTS, THEIR DESIGN, SUITABILITY FOR USE, INSTALLATION, OR OPERATION. OMNI 
INTERNATIONAL WILL IN NO EVENT BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES 
WHATSOEVER, AND THEIR LIABILITY UNDER NO CIRCUMSTANCES WILL EXCEED THE CONTRACT 
PRICE FOR THE GOODS FOR WHICH LIABILITY IS CLAIMED. 

This product has been engineered for safety; however, basic safety precautions and common sense 
must always be demonstrated when using any electrical product. 
- DO NOT attempt to modify any part of this product. 
- DO NOT allow the machine to be submerged in any liquid.
- DO NOT use in any setting other than an indoor laboratory.
- DO NOT plug power cord into an incorrect outlet or subject it to an incorrect voltage.
- Use this product only for its intended purpose.
- DO NOT use attachments not recommended by the manufacturer.
- DO NOT operate the product if it is damaged in any way.
- Keep this product away from heated surfaces.
- DO NOT modify the plug or cord that is provided. If the plug will not fit the outlet, have the proper 
  outlet installed by a qualified electrician.
- DO NOT operate the product with the safety ground disconnected.
WARNING: Reduce the risk of unintentional starting; make sure the speed switch is in the OFF 
position before plugging in the motor.
WARNING: Damaged or worn power cords should be repaired or replaced immediately by a 
qualified electrician.
WARNING: Improper connection of the equipment can result in a risk of electric shock.

Содержание GLH 850

Страница 1: ...en User Manual fr Manuel d utilisation it Manuale d uso es Manual del usuario de Benutzerhandbuch GLH 850 General Laboratory Homogenizer User Manual...

Страница 2: ...F ALL OBLIGATIONS AND LIABILITIES INCLUDING NEGLIGENCE AND ALLWARRANTIES OF MERCHANTABILITY OR OTHERWISE EXPRESSED OR IMPLIED IN FACT OR BY LAW AND STATE OUR ENTIRE AND EXCLUSIVE LIABILITY AND BUYERS...

Страница 3: ...Power Cord 230V LT708 LT712 Cross Rod Plate 50041 50060 1 Clamp FS1002 1 Tool Kit T1001 1 User Manual 03 270 1 Overview 1 2 3 4 5 6 7 8 9 1 Digital Display 2 Speed Control 3 Timer Control 4 Run Butto...

Страница 4: ...and tighten thumb screw by turning clockwise until tight 3 Loosen the second knob on the post clamp and insert the cross rod with motor attached approximately 1 of the cross rod should protrude from...

Страница 5: ...stic probes 1 A1000SB Accessories Generator Probes Plastic Disposable Generator Probes Size Processing Range Type Part No 5 mm x 75 mm 02 mL 5 mL Flat Bottom G5 75 7 mm x 115 mm 25 mL 30 mL Saw Tooth...

Страница 6: ...n button Delayed Start Press and hold the Run button for 3 seconds The display will then countdown for 30 seconds before beginning to run Constant Run Set the timer above 9 59 or below 0 01 The displa...

Страница 7: ...erator probe and attemot to run the motor Check that the generator probe removed from the motor spins freely Check for foreign objects inside the generator probe port Error 2 Motor has failed to reach...

Страница 8: ...NCE ETTOUTE AUTRE GARANTIE DE QUALIT MARCHANDE OU AUTREMENT EXPRESSE OU IMPLICITE EN FAIT OU EN DROIT ET AFFIRME NOTRE ENTI RE ET EXCLUSIVE RESPONSABILIT ET LE RECOURS EXCLUSIF DES ACHETEURS POURTOUTE...

Страница 9: ...50041 50060 1 trier de fixation FS1002 1 Trousse d outils T1001 1 Manuel d utilisation 03 270 1 Aper u 1 2 3 4 5 6 7 8 9 1 Affichage num rique 2 Contr le de la vitesse 3 Contr le de la minuterie 4 Bo...

Страница 10: ...uilles d une montre 3 Desserrer la seconde vis oreilles de l trier de fixation de la tige et ins rer la barre transversale avec le moteur atach environ 1 pouce de la barre transversale doit saillir du...

Страница 11: ...340150 Accessoires G n rateur Jetables Sondes de g n rateur jetables en plastique Taille Plage de traitement Type num ro de commande 5 mm x 75 mm 02 mL 5 mL Embout plat G5 75 7 mm x 115 mm 25 mL 30 mL...

Страница 12: ...ndant 3 secondes et le maintenir enfonc L cran fera alors un compte rebours pendant 30 secondes avant de commencer fonctionner Fonctionnement continu R gler la minuterie au dessus de 9 59 ou en dessou...

Страница 13: ...onctionner le moteur V rifier si la sonde de g n rateur retir e du moteur tourne librement V rifier la pr sence de corps trangers l int rieur du port de la sonde de g n rateur Erreur 2 Le moteur n est...

Страница 14: ...E GARANZIE DI COMMERCIABILIT O ALTRIMENTI ESPRESSE O IMPLICITE DI FATTO O PER LEGGE E STABILISCONO LA NOSTRA COMPLETA ED ESCLUSIVA RESPONSABILIT NONCH LE SOLUZIONI ESCLUSIVE PER GLI ACQUIRENTI IN CASO...

Страница 15: ...060 1 Morsetto FS1002 1 Kit accessori T1001 1 Manuale d uso 03 270 1 Panoramica 1 2 3 4 5 6 7 8 9 1 Schermo digitale 2 Controllo velocit 3 Controllo timer 4 Tasto di avvio 5 Tasto di arresto asta tras...

Страница 16: ...vitando in senso orario 3 Svitare la seconda manopola sul morsetto della barra e inserire l asta trasversale con motore collegato circa 1 dell asta trasver sale dovrebbe sporgere dal lato posteriore d...

Страница 17: ...32750 Adattatore necessario per sonde in plastica 1 15340150 Accessori Sonde Generatore Sonde generatore usa e getta in plastica Dimensioni Intervalli di lavorazione Tipo Numero d ordine 5 mm x 75 mm...

Страница 18: ...ere il tasto Avvio Avviamento Ritardato Premere e tenere premuto il tasto Avvio per 3 secondi Lo schermo mostrer il conto alla rovescia per 30 secondi prima che parta il processo Lavorazione costante...

Страница 19: ...l motore Controllare che la sonda del generatore staccata dal motore giri liberamente Controllare l eventuale presenza di corpi estranei nella porta della sonda del generatore Errore 2 Il motore non r...

Страница 20: ...CUALQUIER GARANT A DE COMERCIABILIDAD O DE OTRO TIPO EXPRESA O IMPL CITADEHECHOOPORDERECHO YESTIPULANUESTRARESPONSABILIDADENTERAY EXCLUSIVA Y LA REPARACI N EXCLUSIVA DEL COMPRADOR EN CASO DE CUALQUIER...

Страница 21: ...era FS1002 1 Juego de herramientas T1001 1 Manual del usuario 03 270 1 Descripci n General 1 2 3 4 5 6 7 8 9 1 Pantalla digital 2 Control de velocidad 3 Control del temporizador 4 Bot n de ejecuci n 5...

Страница 22: ...do en sentido horario hasta que quede apretado 3 Afloje la segunda perilla de la abrazadera del poste e inserte la barra cruzada con el motor adjunto aproximadamente 1 2 5 cm de la barra cruzada debe...

Страница 23: ...50 7 mm x 110 mm Paquete de 50 32750 Adaptador necesario para las puntas de prueba de pl stico 1 15340150 Accesorios Puntas de prueba del generador Puntas de prueba de pl stico desechables para el gen...

Страница 24: ...y sostenga as el bot n de ejecuci n Run durante 3 segundos La pantalla har entonces una cuenta atr s durante 30 segundos antes de empezar a funcionar Ejecuci n constante Programe el temporizador por...

Страница 25: ...e que la punta de prueba del generador extra da del motor gire libremente Busque objetos extra os dentro del puerto de la punta de prueba del generador Error 2 El motor no ha podido alcanzar la veloci...

Страница 26: ...EITEN EINSCHLIESSLICHFAHRL SSIGKEITUNDALLERGEW HRLEISTUNGENDERMARKTF HIGKEITODER AUFANDEREWEISE EXPLIZITODERIMPLIZIT TATS CHLICHODERGESETZLICH UNDSTELLTUNSERE GESAMTE UND AUSSCHLIESSLICHE HAFTUNG UND...

Страница 27: ...V LT708 LT712 Querstrebe Teller 50041 50060 1 Klemme FS1002 1 Werkzeugsatz T1001 1 Bedienungsanleitung 03 270 1 berblick 1 2 3 4 5 6 7 8 9 1 Digitalanzeige 2 Drehzahlsteuerung 3 Timersteuerung 4 Start...

Страница 28: ...rehen Sie die R ndelschraube im Uhrzeigersinn ein bis sie fest sitzt 3 L sen Sie den zweiten Knopf an der St nderklemme und setzen Sie die Querstrebe mit montiertem Motor ein ca 1 der Querstrebe sollt...

Страница 29: ...ck 30750 7 mm x 110 mm 50 St ck 32750 Adapter erforderlich f r Kunststoffsonden 1 15340150 Zubeh r Generatorsonden Kunststoff Einweg Generatorsonden Gr e Verarbeitungsbereich Typ Bestellnummer 5 mm x...

Страница 30: ...e Starttaste Verz gerter Start Dr cken und halten Sie die Starttaste 3 Sekunden lang Die Anzeige z hlt dann 30 Sekunden lang herunter bevor der Durchlauf beginnt Konstanter Durchlauf Stellen Sie den T...

Страница 31: ...Sie ob sich die Generatorsonde vom Motor abgebaut frei dreht berpr fen Sie ob Fremdk rper im Inneren des Generatorsonden Anschlusses sind Fehler 2 Motor hat die gew nschte Geschwindigkeit nicht erreic...

Страница 32: ...PN03 270 Rev C 935 Cobb Place Blvd Kennesaw GA 30144 800 776 4431 770 421 0058 www omni inc com...