![Omicron CMC 430 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/omicron/cmc-430/cmc-430_user-manual_3985327015.webp)
2.9 Generator combination socket
The voltage outputs 1 ... 3 and the current outputs 1 ... 3 are also wired to the
8-pole generator combination socket. This socket is intended to simplify the
connection of test objects to the
CMC 430
.
Please refer to the descriptions of the voltage and current outputs in sections
NOTICE
Equipment damage possible.
Infeed of voltages or currents from external sources may damage the
voltage and/or current outputs.
Technical data and pin assignment →
2.10 Power switch, mains socket, grounding terminal
ON/OFF switch and mains socket.
Nominal voltage: 100 ... 240 V
AC
, 50/60 Hz.
Use the grounding terminal to ground the test object or to provide an additional
ground connection for the test set.