2.2.3 Ethernet interfaces
10/100/1000Base-TX Ethernet ports with Power over Ethernet (PoE) capability. The
port LEDs indicate the link speed and will blink in case of traffic:
Link speed
LED behavior
10 Mbps
Yellow LED active
100 Mbps
Green LED active
1000 Mbps
Yellow and green LED active
2.2.4 USB ports
The
PC
port (USB type B) connects the
CMC 430
to the USB port of the controlling
computer.
The
USB
port (USB type A) is currently used for the USB Wi-Fi adapter only. The
USB Wi-Fi adapter is required for connecting the
CMC 430
to a Wi-Fi network. Only
use the Wi-Fi adapter available from OMICRON or a Wi-Fi adapter that is certified to
work with the
CMC 430
.
With future software upgrades, this port could also support other USB devices like
USB memory sticks, for example.
For best EMC immunity, we strongly recommend to exclusively use the
original high-quality USB cable supplied by OMICRON.
2.2.5 External interface
The external interface provides four transistor outputs and two high-speed
counter inputs. The counter inputs are mainly used for meter testing using
different adapters. This interface also allows the connection of the
CMIRIG-B
accessory.
Technical data and pin assignment →
2.2.6 Expansion ports
The expansion ports allow the connection of up to four external accessories.
CMC 430 User Manual