The "Local Settings" menu allows you to independently configure each scale. This means
that a scale can work, print a barcode, use a different label format than other scales on the
same bench.
These configurations take precedence over other programming if no mode (none) is
selected in the operating mode of the desk.
DEFAULT OPERATIONS
PROGRAMMING
In addition to the
default operations
, the operation mode can also be set
in the bank, family and operator archives. In case of incompatible modes,
operation will be managed according to the following priorities:
1 - Operator
2 - Family
3 - Banco
4 - Default operation
The latter, as you can see, has the lowest priority.
Continuous roll / labels
: the operating modes of the scale are defined when using a
continuous thermal paper roll (adhesive or not) or a roll of labels. By replacing a roll of
paper with one of labels (see "Operator Utilities menu) or vice versa, the scale will
automatically adopt the operating mode specified for that type of roll. The operating modes
allowed are:
1) NONE: no type of operation selected, the default one of the scale model is used
2) TRADITIONAL: possibility of carrying out more weighings in the same account. In the case of
using the
glazing
, the
weight
and the
price
are related to
net weight and not the drained net
weight.
3) SINGLE TICKET: single transaction identifying the operator. In the case of using the
glazing, theweightand thepriceare related tonet weight and not the drained net
weight.
4) AUTOMATIC: single transaction with issuance of the ticket or label automatically
with stable weight. In the case of using the
glazing
, the
weight
and the
price
are
related to
net weight and not the drained net weight.
5) PRE-PACKAGING: the chosen article remains blocked until it is canceled or
another article is recalled; the ticket or labels are printed at each weight
variation In this mode the label will not be issued with weights lower than 20
divisions (e.g. for a 2g the
minimum weight
is 2 x 20 = 40 grams). In the case of
using the
glazing
, the
weight
and the
price
are related to
drained net weight
. For
full-body articles, printing takes place when the Single-Ticket button is
pressed. With body items it is possible to set the number of labels to be
printed, setting the number of labels is done by pressing the multiplication
key twice after recalling a PLU. The first time the key is pressed
"X "
the
multiplier is requested, which by default is 1 the second time the number of
labels is requested.
This method is not allowed in direct sales to the public.
Freestyle Compact user manual
Rev.1
Page 44 of 92
Содержание FREESTYLE COMPACT CS
Страница 1: ...USER MANUAL FREESTYLE COMPACT Translated from Italian to English www onlinedoctranslator com...
Страница 2: ...VIEW AND DIMENSIONS MODEL CS Freestyle Compact user manual Rev 1 Page 2 of 92...
Страница 3: ...MODEL CS P wall unit CS PA MODEL Freestyle Compact user manual Rev 1 Page 3 of 92...
Страница 4: ...PLC MODEL Freestyle Compact user manual Rev 1 Page 4 of 92...
Страница 5: ...MODEL PL Freestyle Compact user manual Rev 1 Page 5 of 92...