11
Operation
Maintenance
HOW TO USE THE MIXER
With the on/off switch in position “0” fill the mixer. The food product to be mixed must be contained within the
mixing drum and must not exceed the consented weight. Close the grill and start the mixer.
NOTE
To preserve the freshness and integrity of the meat, we recommend working the meat at a maximum
temperature of 7°C / 44.6°F and terminating the process within 10 minutes. Once the meat has been
processed, thoroughly clean all the machine parts. After every work cycle, we recommend leaving the mixer to
rest for a few minutes before using it again. The machine is not designed for working inside a cold room: this
could seriously damage the electrical components sensitive to condensate (which forms at low temperatures)
and also alter the viscosity of the grease and/or lubricating oil in the gearboxes and cogs inside it, jeopardizing
the machine’s correct operation and causing potential failures.
AUTOMATIC USE (FIG. 4.1.2)
AUTOMATIC MIXER
1. Press the drive push-button “1”: the blades will start turning and the indicator light “4” will go on.
2. Press the reverse drive push-button “3”: the indicator light “5” will start flashing. After 30 seconds, the
machine will automatically reverse drive. Every 30 seconds it will invert blade rotation. After 2 minutes (4
cycles) the machine will automatically stop.
AUTOMATIC SWITCH-OFF
1. Press the drive push-button “1”: the blades will start turning and the indicator light “4” will go on.
2. Press the drive push-button “1” again. After 1 minute, the machine will automatically stop. The same
sequence can be run in reverse drive.
EMPTYING AND CLEANING
EMPTYING THE MIXING BOWL
Turn off the mixer, the on/off switch is in position “0” unplug from main power supply. The mixing bowl is
designed to rotate to facilitate emptying.
• With the bowl in a horizontal position grip the handle on the bowl titling bar “1” Fig. 6.3.1.
• Pull the tank locking knob “2” Fig. 6.3.1.
• Once having released the mixing bowl rotate (Fig. 6.3.2) by pulling the tilting bar “1” Fig. 6.3.1.
• Open the protection grille “3” Fig. 6.3.2 and empty the bowl.
CLEANING THE MIXING BOWL
With the machine off and switch in position “0” and with the plug removed from the socket proceed with
cleaning the bowl. Thanks to the possibility of rotating the bowl cleaning operations are facilitated.