PV8355F4E007 II 

Table of Contents 

Description of Precautions,    Rated Display, and Symbol 
Marks ······································································ 1

 

Safety Precautions ····················································· 3

 

Features of this Product ·············································· 6

 

1.

 

Confirmation of Packaged Products ························· 7

 

2.

 

Part Names and Functions/Specifications ················· 9

 

3.

 

Equipment

 

Installation and Connection ···················  12

 

4.

 

Usage ······························································ 14

 

5.

 

Notes on Storing ················································ 23

 

6.

 

If Abnormality Occurs·········································· 23

 

7.

 

Conforming to Laws and Regulations ······················· 23

 

Appendix ································································ 24

 

To customers who execute micro-spectrometry by placing a 

sample on the tilt stage 

Cleaning the transmission window glass 

 

Содержание USPM-RU-W Series

Страница 1: ...letely before use This manual describes only the contents of the transmit unit thus read this manual together with the instruction manual for the NIR Micro spectrophotometer USPM W B in the attached s...

Страница 2: ...rmation of Packaged Products 7 2 Part Names and Functions Specifications 9 3 Equipment Installation and Connection 12 4 Usage 14 5 Notes on Storing 23 6 If Abnormality Occurs 23 7 Conforming to Laws a...

Страница 3: ...or our service department for replacement or other inquiries Mark Description Do not touch because the surface is hot Otherwise you can get burned Indicates a warning or caution covering a wide range...

Страница 4: ...this product are as follows Indicates the proper upper direction of the packaged cargo Indicates that the packaged cargo must not be exposed to rain Indicates that packaged cargo must be carefully ha...

Страница 5: ...ated equipment simultaneously used in a location where you can refer to them immediately Contact the retailer or our service department if you have any questions regarding the contents of this instruc...

Страница 6: ...on manual of the NIR Micro spectrophotometer USPM W B Observe the cautions below when handling this product Notice that each chapter also describes each caution Gently operate each adjustment knob Gen...

Страница 7: ...during correct usage compliant with the manual and warning labels during the warranty period 2 We do not warrant any failure due to other causes e g peripheral device s or the environment at the insta...

Страница 8: ...e accuracy of the contents of this document if you discover any unclear point or mistakes omissions please consult with the contact point listed in the attached sheet Regardless of the preceding provi...

Страница 9: ...set and supplied accessories are completely received and check whether products are missing or damaged Contact the retailer or our service department immediately without using the products if parts a...

Страница 10: ...or unit for transmittance and tilt stage Name Quantity Remarks 3 collimator unit for transmittance 1 1 4 Tilt stage 1 1 5 Lamp housing 1 6 Lamp cable 1 7 Halogen lamp exclusively used for this device...

Страница 11: ...llimator unit for transmittance This consists of a light source unit used for optional transmission measurement and 45 degree measurement Fix the lamp housing using the two fixing knobs For more detai...

Страница 12: ...djustment knob 4 Polarization unit This unit adjusts the polarization state to P S or random polarization using a polarization switching knob Polarization switching knob Tilt adjustment knob Adjusts t...

Страница 13: ...s Specifications Name Transmittance Measurement Unit Type USPM TU Wavelength range 380 to 1050 nm Wavelength resolution Approx 5 nm Wavelength display resolution 1 nm Repeatability 3 0 3 or less 430 1...

Страница 14: ...levers 4 Insert the lamp housing into the former position Adjust it so that the lamp connector faces the right of the device Check the encircled part and then check the screw hole position and the la...

Страница 15: ...erformance cannot be secured when the wall outlet is not grounded 5 Protection key Any USB port on the computer The power cord may melt and short circuit if it makes contact with the lamp housing Keep...

Страница 16: ...Option Customers who purchase a polarization unit See 4 5 Polarization state settings 5 Set a work setting file See 4 6 Setting a work setting file For reference setting select FIXED and enter 100 6...

Страница 17: ...double click the shortcut icon on the desktop and start the program 4 3 Revolver settings 1 Set a revolver A revolver is adjusted to the through position in which an objective lens is not installed wh...

Страница 18: ...tion you want to measure The polarization direction faces the stage surface Refer to the figure below Gently operate the optical path switching knob used for the optical switching unit Applying excess...

Страница 19: ...setting file For more details see 6 2 Work setting in the Software Instruction Manual USPM SA 1 Select Set Work from the file menu A WORK setting window appears 2 Set the reference 1 Click and fix FI...

Страница 20: ...t position of the FOCUS window 3 Adjust the outgoing beam s tilt of reference standard light flux For the tilt adjustment of a reference standard light flux observe the FOCUS window of the software an...

Страница 21: ...on measurement Adjust the numeric value Y displayed in the upper left position of the CT window to Y 0 1 4 8 Adjusting the sampling time Adjust the sampling time so that the spectral light intensity...

Страница 22: ...E in the operation panel 4 11 Setting a measurement sample 1 Install the measurement sample on the upper surface of the tilt stage The measurement sample is placed at the holed point in the center of...

Страница 23: ...the measurement result are displayed on the TEXT window 3 DIAGRAM window The measurement result of the chromaticity diagram is displayed on the DIAGRAM window XY and Lab chromaticity diagrams can be d...

Страница 24: ...line indicates the lower limit of the spectroscopic quantity defined in the system configuration window 6 LUMINANCE TEXT window Each spectral light intensity of a background reference and measurement...

Страница 25: ...urs Make confirmation through the combined use of 6 If Abnormality Occurs in the instruction manual for NIR Micro spectrophotometer USPM W B 7 Conforming to Laws and Regulations See 7 Conforming to La...

Страница 26: ...is adjusted to the through position in which an objective lens is not installed 4 Install a BK7 reference sample in the tilt stage 5 Adjust the tilt of two axes to the optical axis using the tilt sta...

Страница 27: ...in the instruction manual for the NIR Micro spectrophotometer USPM W B and remove the work installing plate 2 Adjust the scale of the shift stage to point 0 3 In the figure below the transmission wind...

Страница 28: ...l rights reserved The contents of this manual shall not be reproduced or distributed in part or in whole without Olympus s consent The company and product names described in this manual may be tradema...

Страница 29: ...A CO LTD 8F Olympus Tower 446 Bongeunsa ro Gangnam gu Seoul Korea 135 509 Tel 82 2 6255 3458 OLYMPUS THAILAND CO LTD 159 Serm mit Tower 9th floor unit 906 910 Sukhumvit21 road North Klongtoey Wattana...