![Olympic Calstar A10Ex Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/olympic/calstar-a10ex/calstar-a10ex_operation-and-maintenance-handbook_3849212032.webp)
Calstar
操作及保養
說
明書
OPERATION AND MAINTENANCE
HANDBOOK
A10Ex
32
3
)
熱媒油是否長久尚未更換
﹒
(
Check if the Heat
Transfer Oil has not been replaced for a long
time.
)
C)
回收廢液中溶劑之成
份並不知道
. (
The
percentage composition of the mixture solvent-
pollutant is not known exactly.
)
1
)
設定加熱
溫度控制器在
160
℃
.(
Set the
distillation thermostat at 160°C.
)
2
)
設定關機
溫度控制器在
50
℃
﹒
(
Set the
automatic-cut-off thermostat at about 50°C.
)
3
)
等到乾淨溶劑流出時
,
降低
溫度控制器
温度
,
直
到綠色指示燈及電風扇同時關掉
.(
When the
recovered solvent starts to flow out, slowly lower
the temperature set of thermostats until the green
warning light and the axial flow fan switch off
simultaneously.
)
4
)
此時關機
溫度控制器上之溫度即是溶劑之沸點
.
由此溶劑之沸點再依照
“
溫度控制器之設定
”
重新設定
溫度控制器即可
﹒
(
Read on the
automatic-cut-off thermostat knob the temperature
which corresponds to the solvent boiling
temperature. Execute the setting of the thermostats
using the taken temperature to obtain the perfect
working of the Solvent Recovery Machine and the
automatic switching off at the end of the cycle.)
D)
回收機無法將全部之溶劑回收出來
﹒
(
The unit does not recover all of the polluted
solvent content.
)
檢
查溫度控制器之設定是否正確
.
(Check if the
setting of the thermostats is correct.)
E)
機器正常運轉
﹐但是溶劑無法流出﹒
(
The
unit works but the recovered solvent does not
come out.
)
檢
查是否因為進料太多造成管路阻塞
(
Check if
the condensing coil is obstructed because of the
solvent tank overfilling. For checking, it is
necessary to
):
1 )
打開桶蓋
﹒
( Open the lid)
2 )
由溶劑出水口吹入
0.2Bar
壓縮氣體
﹐檢查是否
有足
夠之空氣吹出(請參照
“
13
﹒
3
”
檢
查)﹒如果
有阻塞現象
,
請與
Calstar
公司或當地代理商聯
繫
﹒
(
Blow air at a pressure of 0.2 Bar inside the outlet pipe
for the recovered solvent, checking if there is an
adequate air passage (see paragraph 13.3 “Checking
Procedure”). If not, contact the
Calstar
Company or the
nearest authorized reseller for the steam pipe
disassembly and the obstructions removal.
)
F)
回收出來之溶劑不乾淨
﹒
(
The
recovered solvent comes out dirty.)
1
)
進料過多
﹐超過最高液位線﹒
( The solvent tank
has been filled over the maximum capacity line.)
2
)
回收廢液會發泡
﹐此時請減少進料容量﹒
( The
dirty solvent is mixed together with very particular
foamy products, thus making necessary a lower
filling of the solvent tank.)
3
)
當上述
2
種情況發生時
,
冷凝管路會
污染及阻塞
,
請用
5
公升之乾淨溶劑進行回收以便清洗冷凝管