Calstar
操作及保養
說
明書
OPERATION AND MAINTENANCE
HANDBOOK
A10Ex
19
及
M
6
之金屬膨脹型螺絲固定
﹒
(For a safe working, the unit must be fastened to the floor by screw anchors. For this purpose, use the
four holes on the unit feet. The screw anchors must be of expansion metallic type with metric M6
screws.)
10.0
組裝
(SETTING AT WORK)
每次只要有關於電力方面之操作
﹐縱然很簡單﹐還是需要專
門技術電工來執行
.
Even the operation of the electrical panel is easy, it still requires
the labor of professional workers.
10.1
接電
(Electrical connection)
本機器除需接電之外
﹐不需要任何輔助裝置﹒
(The unit does not need further
devices or operations to be set at work, except the execution of the electrical connection.)
A10Ex
機器配有
3*2.5
㎜
2
護套電纜
﹐接電必須接在工作場所之電力供應末端﹐必須使用手
動式分區供電之裝置
﹒此裝置可在必要的情況下將機器之電機系統與供電系統分開﹒
(A10Ex unit
is equipped with 3* 2.5
㎜
2
cable. The connection must be directly executed at the terminals of the source
of the power supply existing in the work place. It is necessary for the presence of a feeding sectioning
device by manual control. This device is able to allow the separation of the unit electrical equipment from
the general feeding system.)
供電裝置如果位於遠離操作間之安全區,亦可採用非防爆之供電裝置
. (
If the power
supply device is located in a safe area away from the operation area, then it is allowed to
use non-anti-explosion power supply device.)
分區供電裝置如果位於操作間,必須採用符合中華人民共和國國家標準
GB3836
系
列,與
產品使用環境相適應的防爆供電開關
.
且不低於回收機的防爆標誌。
(If the power
supply device is located in the operation area, it must match the regulation of “PRC
national standards GB3836”, and it must be suited to the use of environmental anti-
explosion switches.)
此裝置必須能負載
20A
電流
﹒機器輿電纜必須接地。
(The device must be able to
manage 20A currents. Additionally, the unit and the meter cable must be grounded.)
回收機的電氣
佈線應符合
GB3836.15-2000
《爆炸性氣體環境用電氣設備
第
15
部
分:危險場所電氣安裝(煤礦除外)》的規定。
(The electrical wiring of the Solvent
Recovery Machine should meet the regulations of GB3836.15-2000
《
Using Electrical
Equipment in Explosive Gas Environment Part 15: Electrical Installation within Dangerous