Before check-up please turn off the softener inlet valve or bypass valve to bypass
position. Prohibit the use of harmful health detergents or chemicals to clean, wipe the
device. Wipe with a moistened soft fabrics to clean equipment surface dust and foreign
matter, avoid the water into the valve internal erosion electrical components causing
damage.
Disassembly way (Before disassembly, the device should be under brine status that will
make it convenient for maintenance)
12. MAINTENANCE
Uninstall dustproof cover assembly
Press inward the decorative part and pull
outward the dustproof cover buckle. Set apart
the front two buckle positions and pull upward
the cover, then set apart the rear buckle
positions and disassemble the dustproof cover
assembly.
Softener
Uninstall bypass valve
Pull out the clips in the bypass, uninstall the
bypass backward. Unscrew the hex nut, pull out
the brine tube (with plug), take out the drain
line flow control, loosen the clamp, pull out
drain pipe.
Uninstall control valve
Take out the wrench fixed on
the decorative part, wedge it in
the height increaser, reserves
the control valve, and uninstall
the valve body.
Inside emptying
Remove the elements inside
the cabinet, to make room for
the tank.
Remove resin tank
Use the special-purpose life
to screw the resin tank, and
take out the valve body.
Take out resin tank
OLYMPIA PLUS-CEASA 55
Содержание 160 V HF UF
Страница 1: ...MANUAL DE INSTRUCCIONES ES INSTRUCTION MANUAL EN MANUEL D INSTRUCTIONS FR 1...
Страница 2: ......
Страница 30: ......
Страница 31: ...INSTRUCTION MANUAL EN OLYMPIA PLUS CEASA 1...
Страница 32: ......
Страница 61: ...MANUEL D INSTRUCTIONS FR OLYMPIA PLUS CEASA 61...
Страница 62: ......
Страница 90: ...90 OLYMPIA PLUS CEASA...
Страница 91: ...OLYMPIA PLUS CEASA 91...