589402
User Manual
2-3
Figure 2-4 Blue-coloured display screen after Bed Setting is selected
4.
Press the jog dialer again.
The extruder assembly moves to the first Adjustment position (there are 5 in total). Try to pass the 0.10 mm
feeler gauge supplied between the Extruder 1 nozzle and the tempered glass. If the feeler gauge moves
freely between the nozzle and the glass, you must work on the reference self-locking nut turning it in the
clockwise direction until no light passes between the glass/ gauge/nozzle. In the opposite case
– if the
nozzle is too near the glass (i.e. feeler gauge cannot be inserted) - then work on the nut in the opposite
direction (i.e. anti-clockwise), until the right amount of space is left between the nozzle and the table.
Содержание S2
Страница 1: ...Printer 3D Olivetti S2 USER MANUAL Code 589402...
Страница 10: ...vi User Manual 589402 This page is intentionally left blank...
Страница 36: ...2 18 User Manual 589402 This page is intentionally left blank...
Страница 54: ...A 4 User Manual 589402 This page is intentionally left blank...
Страница 58: ...C 2 User Manual 589402 This page is intentionally left blank...
Страница 63: ...589402 User Manual F 2 This page is intentionally left blank...