Y101700-5
Service Manual
6-9
Content
Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Setting
0
0 sec
1
30 sec
2
60 sec
3
90 sec
Transfer ON timing control setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
(For any number different from the following ones, the default time is automatically
set.)
Code number
Setting
0
Default (330 msec)
1
–40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
Default (330 msec)
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void
amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
Code number
Setting
0
0 mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm *Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Main code
26
Sub code
40
42
43
Содержание d-Copia 12
Страница 1: ...d Copia 12 Copier SERVICE MANUAL Code Y101700 5 ...
Страница 4: ...vi Service Manual Y101700 5 ...
Страница 18: ...Service Manual Y101700 5 1 14 ...
Страница 72: ...Y101700 5 Service Manual 7 1 7 MAINTENANCE 7 1 Maintenance table 7 2 Maintenance display system ...
Страница 73: ...Service Manual Y101700 5 1 14 ...
Страница 74: ...Y101700 5 Service Manual 8 1 8 ELECTRICAL SECTION 8 1 Block diagram 8 1 1 Overall block diagram ...
Страница 75: ...8 2 Service Manual Y101700 5 8 2 MCU PWB unit ...