Oliver Packaging & Equipment Company
3236 Wilson Drive NW, Walker, MI 49534
(800) 253-3893
747-N BREAD SLICER
0747S20007
6-15
WARNING
ALWAYS DISCONNECT THE SLICER FROM THE POWER SUPPLY BEFORE
ATTEMPTING ANY TYPE OF MAINTENANCE TASK.
Adjusting the Clearance Between the Blade Frames (continued)
When the eccentric pins are in the desired position tighten each of the locknuts to secure
the position of the eccentrics. Check the blade frame clearance by manually turning the
belt by hand and listening for part-to-part contact. If there is contact further eccentric
adjustment is required to move the blade frames apart. If the blades are not inline, the
blade frames may hit each other causing a loud knocking noise while running and/ or the
cutting efficiency of the machine may be greatly reduced. When the adjustment is
satisfactory, lock the eccentric pins by tightening the lock nuts while holding the
eccentric pin from turning. Replace the push button panel and the outfeed tables before
starting the machine.
Cleaning
Use a mild detergent solution to clean the exterior surfaces and empty the crumb tray
daily or as necessary. Periodically remove all covers and brush all foreign material from
all surfaces, especially moving parts.