0619S20133
5-1
619-MDP DOUGH PRESS
TROUBLE SHOOTING GUIDE
The “Ram Up Light” does not come on.
Possible Causes
·
There may be a disconnected wire.
·
The pilot light may have burnt out.
·
The pressure switch is not operating and needs replacement.
The motor “Hums” but will not start.
Possible Causes
·
The motor is a dual voltage motor and may be wired for high voltage, but, an
attempt is being made to run it on low voltage.
·
The electric supply to the motor is single phase instead of three phase.
·
One of the leads of the three phase system has opened.
The motor runs but “Stalls” at either end of the cylinder’s travel.
Possible Causes
·
The incorrect overload relay was installed or the setting of that overload
relay is incorrect.
·
The setting of the hydraulic relief valve is too high.
·
The motor is running backwards and needs its rotation corrected. See
“Before You Start” in the Operating Instructions.
Содержание MODEL 619-MDP
Страница 5: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 8: ...0619S20130 2 3 Electrical Wiring Diagrams Continued 3 ph 60 hz 208 230 VAC 3 ph 60 hz 460 VAC ...
Страница 20: ...0619S20135 7 1 619 MDP DOUGH PRESS MAIN FRAME ...
Страница 22: ...0619S20144 8 1 619 MDP DOUGH PRESS COVER ASSEMBLY ...
Страница 25: ...0619S20137 9 1 619 MDP DOUGH PRESS HYDRAULIC ASSEMBLY Rev 10 25 05 ...
Страница 27: ...0619S20138 10 1 619 MDP DOUGH PRESS LID ASSEMBLY ...
Страница 29: ...0619S20139 11 1 619 MDP DOUGH PRESS PUSHER ASSEMBLY ...
Страница 31: ...0619S20140 12 1 619 MDP DOUGH PRESS ELECTRICAL ASSEMBLY ...
Страница 33: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 35: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 37: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...