TROUBLE SHOOTING GUIDE
The “End of Stroke Light” does not come on.
Possible
Causes
•
There may be a disconnected wire.
•
The bulb may have burnt out.
•
The limit switch is not adjusted properly.
•
The limit switch is not operating and needs replacement.
The motor “Hums” but will not start.
Possible
Causes
•
The motor is a dual voltage motor and may be wired for high voltage, but an
attempt is being made to run it on low voltage.
•
The electric supply to the motor is single phase instead of three phase.
•
One of the leads of the three phase system has opened.
The motor runs, but, “Stalls” during the cylinder’s stroke.
Possible
Causes
•
The incorrect overload relay was installed or the setting of that overload
relay is incorrect.
•
The setting of the pressure relief valve is to high.
•
The motor is wired for high voltage but is connected to a low voltage supply.
Continued
Содержание 619-16A
Страница 5: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 8: ...0619S20058 2 3 Electrical Wiring Diagrams Continued 3 ph 60 hz 208 230 VAC 3 ph 60 hz 460 VAC...
Страница 21: ...0619S20052 7 1 MAIN FRAME ASSEMBLY...
Страница 23: ...0619S20053 8 1 COVERS ASSEMBLY...
Страница 25: ...0619S20054 9 1 HYDRAULIC ASSEMBLY Rev 12 21 04...
Страница 27: ...0619S20055 10 1 LID ASSEMBLY...
Страница 29: ...0619S20056 11 1 ELECTRICAL ASSEMBLY Rev 11 27 02...
Страница 31: ...0619S20057 12 1 PUSHER ASSEMBLY 16 Part Pusher Assembly Shown for Reference Only...
Страница 33: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 35: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 37: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...