0619S20049
4-1
MAINTENANCE
WARNING
ALWAYS MAKE SURE THE MACHINE HAS BEEN DISCONNECTED
FROM THE POWER SUPPLY BEFORE CLEANING OR SERVICING.
Cleaning
The exterior and contact surfaces should be cleaned daily using common cleaners. The
knives should be extended for easier cleaning. This can be done by placing the cleaning
separator, furnished with the machine,
IN THE CENTER OF THE HOPPER
straddling
the knives. Close the lid and bring the floor of the hopper up until the light on the manual
starter is on, lower the floor slightly. Open the lid and disconnect the divider from the
power supply. Clean the knives and plastic compartment floors of all dough build-up.
CAUTION
IF NOT CLEANED A BUILD-UP OF DRIED DOUGH BETWEEN THE
PLASTIC FLOORS AND THE KNIVES COULD DAMAGE THE DIVIDER.
In addition to the general cleaning discussed above, it is important that you check for
and remove scraps of dried dough from between the blade holder and the bottom thrust
plate. This can be done by first extending the knives as described above and then by
removing the front and rear covers from the machine by removing the eight thumb
screws and the control valve handle knob. This will allow access to the blade holder
area, which can then be cleaned of all dried scraps of dough. When finished replace the
covers and knob.
CAUTION
FAILURE TO CLEAN DRIED DOUGH FROM THE BLADE HOLDER AND
THRUST PLATE COULD RESULT IN SEVERE PUSHER DRIVE DAMAGE.
Occasionally, as required, you should also remove the build up of flour and dough
particles in the base of the machine around the motor.
Lubrication
The machine requires no lubrication but the oil level in the hydraulic system should be
checked periodically. To check the oil level remove the rear cover by removing the four
knobs which secure it to the divider, then remove the tank breather/cap and determine
where the top of the oil is in relation to the top surface of the tank. Fill with oil to within
approximately one inch of the top surface. If necessary add
HYDRAULIC OIL
to return
it to the proper level,
DO NOT OVERFILL
. In addition to the above we advise replacing
the hydraulic oil in the system approximately every three years.
Содержание 619-16A
Страница 5: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 8: ...0619S20058 2 3 Electrical Wiring Diagrams Continued 3 ph 60 hz 208 230 VAC 3 ph 60 hz 460 VAC...
Страница 21: ...0619S20052 7 1 MAIN FRAME ASSEMBLY...
Страница 23: ...0619S20053 8 1 COVERS ASSEMBLY...
Страница 25: ...0619S20054 9 1 HYDRAULIC ASSEMBLY Rev 12 21 04...
Страница 27: ...0619S20055 10 1 LID ASSEMBLY...
Страница 29: ...0619S20056 11 1 ELECTRICAL ASSEMBLY Rev 11 27 02...
Страница 31: ...0619S20057 12 1 PUSHER ASSEMBLY 16 Part Pusher Assembly Shown for Reference Only...
Страница 33: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 35: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Страница 37: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...