UNICO TWIN
ENGLISH
EN - 29
d.
increase or decrease the time at which you desire the air conditioner deactivates by means of the tilt
selector
T7
. the variation of the settable time with selector
T7
is of 30 minutes.
e.
Press selector
T7
again; the symbol
2
(U9) appears on the display (Switch-on time of the 2° program).
f.
increase or decrease the time at which you desire the air conditioner activates by means of the tilt
selector.
the variation of the settable time with selector
T7
is of 30 minutes.
g.
Press key
T6
a second time; the symbol
2
(U9-UY) appears on the display (Switch-off time of the 2°
program).
h.
increase or decrease the time at which you desire the air conditioner deactivates by means of the tilt
selector
T7
. the variation of the settable time with selector
T7
is of 30 minutes.
i.
Press key
T6
once or more until all the symbols referring to this setting switch off to return to the normal
mode of operation.
5.5.3 - TIMER ACTIVATION AND DEACTIVATION
once set, the timer programs can either be activated or deactivated depending on occasional needs.
activation may relate to one of the two programs or both.
in particular, each time you press key
T1
(Set timer) (Programs activation), situation changes as follows:
• Use of Program no. 1 only.
• Use of Program no. 2 only.
• Use of Programs 1 and 2.
• Disuse of both programs
5.6 - DIAGNOSIS, ALARMS AND INCONVENIENCES
5.6.1 - DIAGNOSIS OF THE INCONVENIENCES
it is important for the User to distinguish between functional problems and anomalies in relation to the be-
haviour of the appliance as foreseen for its normal operation.
furthermore, the most common problems may easily be solved through simple operations on behalf of the
User (See paragraph: anomalies and solutions).
For all the other reports (see paragraph: 5.6.2), it is necessary to always contact
the technical assistance service”
Any attempt to repair the appliance by unauthorised personnel will immediately
invalidate any form of guarantee.
5.6.2 - RUNNING TESTS AND TROUBLESHOOTING
the conditioner is able to perform a brief auto-diagnosis cycle to check that the internal components are
operating normally and during which it is possible to perform the configuration of the electronic control based
on whether installation of the appliance was performed to the upper part (to the ceiling) or lower part (to the
ground) of the wall.
to activate the self-diagnosis function, proceed as follows:
- Power the appliance by connecting it to a socket or by acting on the master switch of the system;
- ensure that the machine is on stand-by (no leD should be lit on the console);
- Press the micro-key positioned underneath the hole to the left side of the console with a pointy object
for at least 10 seconds. the acoustic signal emitted indicates that the self-diagnosis function has been
activated.
Содержание Unico Twin
Страница 2: ......
Страница 7: ...2 3...
Страница 8: ...min 300mm 8mm min 1500mm 8 6 9 7 H 6a N M Y 4 5...
Страница 9: ...10 202 mm G 162 mm 130 mm G 12 11 G F D F G 13 14...
Страница 10: ...6mm 15 19 17 16 20 18 F E E E...
Страница 11: ...21 H L1 L H A A1 H L L1 24 22 23 L...
Страница 12: ...28 29 max 43mm 26 27 25 Wd Wh We Wf Wc Wb Wg Wa Wi Wc Wb Wa...
Страница 13: ...L G N B A 34 32 33 35 J1 J2 P1 P1 21 22 23 P2 30 31 X1 X2...
Страница 14: ...36 CLICK 40 8m 8m 37 38 39 10...
Страница 15: ...AUTO OFF 43 42 41 3 F 40a 40b 40c...
Страница 16: ...44 45 F1 F2 F1 F2 46 L N G B A POWER TO MASTER...
Страница 247: ......
Страница 248: ...262286A...