ENGLISH
EN - 11
2 - CORRECT USE OF THE APPLIANCE
2.1 - WARNINGS
A failure to respect what follows may cause damages to the appliance.
a.
Make sure that curtains or other objects do not obstruct the air suction filters.
b.
The appliance must always be used paying attention that there are no obstructions
for the intake and outlet of air.
c.
The appliance must not be used in laundry rooms.
d.
The appliance must never be used in the presence of hazardous materials, vapours
or liquids.
e.
If the appliance is used frequently, clean the air filters at least every two weeks.
2.2 - OPERATING CONDITIONS
For safe and effective operation, use the appliance at the following temperatures.
Mode
External temperature
Room temperature
Water inlet
temperature
Cooling
21°C
~
43°C
17°C
~
32°C
3°C
~
20°C
Heating mode
(not available in cooling
only models)
-5°C
~
24°C
0°C
~
30°C
30°C
~
70°C
NOTE:
•
If the appliance is not used within the values indicated, operating anomalies may occur.
•
IT IS normal that condensate forms on the surface of the appliance when the level of humidity in the
room is high; in this case, close doors and windows.
•
Operating pressure of the hydraulic system: Max: 1.6 MPa - Min: 0.15 MPa