background image

1.4 DANGER OF EXPLOSION DURING EXCAVATION

Unfortunately, the last two world wars and other local conflicts made the ground in many places 
of the world a potentially explosive scrap heap. A host of those lethal relics are still buried in the 
ground. Do not start digging and hacking for an object wildly when you receive a signal of a piece 
of metal from your device. Firstly, you might indeed cause irreparable damage to a truly rare find, 
and secondly, there is a chance that the object reacts in an insulted way and strikes back.

Note the color of the ground close to the surface. A red or reddish color of the ground is an in-
dicator of rust traces. As regards to the finds themselves, you should definitely pay attention to 
their shape. Curved or round objects should be a sign of alarm, especially if buttons, rings or little 
pegs can be identified. The same applies to recognizable ammunition or bullets and shells. Leave 
ammonition where it is, do not touch it and, most importantly, do not take any of it home with you. 
The devices of war made use of rocker fuses, acid fuses and ball fuses. Those components have 
been rusting away in the course of time, and the slightest movement may cause parts of them to 
break and be Triggered. Even seemingly harmless objects such as cartridges or large ammunition 
are anything but that.  

Moving such an object may cause those crystals to produce friction, leading to an explosion. If you 
come across such relics, mark the place and do not fail to report the find to the police.  Such ob-
jects always pose a danger to the life of hikers, walkers, farmers, children and animals.

1.5 CARE AND USE

The Rover UC is a sturdy instrument, but it is not designed to withstand abuse. In caring for your 
ground scanner, there are several important DOs and DON‘Ts to remember:

• 

DO NOT use to get rid of bushes, flatten area by swinging wildly or pry rocks loose. 

• 

DO NOT drop the machine into water or use it while it is raining or wet.

• 

DO NOT leave it exposed at night where dew could form on it. 

• 

DO NOT store it in places that could get extremely hot. 

• 

DO NOT leave it in the trunk of a car where high temperatures could build up. 

• 

DO NOT spray lubricants, or any type of cleaners, solvents, sealants or other chemicals into 
or onto the electronic parts, switches or controls.

• 

DO NOT attempt to modify or repair the detector‘s electronics as this will void your detector‘s 
warranty.

• 

DO clean your unit with a soft dry or slightly damp cloth to remove dust and residue from the 
previous use.

• 

DO use the device within the proper operating guidelines.

The warranty does not cover damage resulting from an accident, neglect or abuse.

1.6 PROTECTING YOUR INVESTMENT

Often detector users become disappointed when their new detector becomes less and less  
responsive and seems to have lost some of its original peak performance. You can help prevent 
this from happening to your detector by following these basic care and protection guidelines:

• 

Operate your detector exactly as recommended in this User Manual.

• 

Use only approved OKM chargers.

• 

Avoid hitting the probe against hard, solid objects and surfaces.

• 

Keep your probe slightly off of the ground, especially when using in gravel or hard, rocky dirt.

• 

If working in or near water, or if there is a possibility of rain, use a protective weather resistant 
pouch or plastic bag to cover the control housing. Make sure it can “breathe” in order to ensure 
against condensation buildup inside.

• 

After each use, clean the detector with a soft cloth to remove dust, moisture or other conta-
minants.

• 

When transporting the detector in a car during hot weather, store it on the floor of the pass-
enger compartment if possible. Using the Protection case gives additional protection. In any 
case, never allow the detector to roll around unprotected in the trunk or back of a pickup truck.

• 

Protect your detector from dust, moisture, and extreme temperatures during storage.

• 

When shipping, use the original heavy-duty container (Protection case) and provide sufficient 
padding around all parts.

• 

Treat your detector as you would treat any sensitive electronic instrument. Though it is  
designed to withstand the demands of normal treasure hunting, proper care is essential.

6 / 34

Содержание Rover UC

Страница 1: ...INTRODUCTION TECHNICAL SPECIFICATIONS CONTROL ELEMENTS ASSEMBLY PREPARATION OPERATING MODES FILE TRANSFER OKM ROVER UC MANUAL...

Страница 2: ...ated with the delivery exploitation or usage of this material This documentation is available as presented and without any kind of warranty In no circumstances OKM takes responsibility for lost profit...

Страница 3: ...S 11 4 ASSEMBLY AND PREPARATION 13 5 OPERATING MODES 14 5 1 ACTIVITY SCREEN 14 5 1 1 Pedometer Reset 15 5 1 2 Compass Calibration 15 5 2 3D GROUND SCAN 16 5 2 1 Preparing a 3D Ground Scan 16 5 2 2 Per...

Страница 4: ...be successful and have a find during the course of your research The recognition of hidden and buried objects depends on a huge number of factors As you well may know there are different soil types al...

Страница 5: ...uld have evaporated The unit is not weather proof and water or condensation can destroy the unit Avoid strong magnetic fields which may occur in places where there are large electric motors or unshiel...

Страница 6: ...d form on it DO NOT store it in places that could get extremely hot DO NOT leave it in the trunk of a car where high temperatures could build up DO NOT spray lubricants or any type of cleaners solvent...

Страница 7: ...isplay LCD 80 x 160Pixel Sample rate 240 values second Measurement resolution 15bit Interconnect Bluetooth 5 2 max distance 8m Operating temperature 5 60 C Storage temperature 10 70 C Air humidity 5 7...

Страница 8: ...n this section you learn more about the fundamental use of all control elements for this measur ing instrument All connections inputs and outputs are explained in detail Telescopic Probe Smartwatch CO...

Страница 9: ...owered on but is not connected to any Android device via Bluetooth Trigger LED blue Detector is powered on and connected to an Android device Smartwatch or Smartphone via Bluetooth The detector is rea...

Страница 10: ...on B Long press Button B min 2 s to power on the Smartwatch or if Smartwatch is switched on to enter the Shutdown screen From here you can choose between Power off Reboot Power Save or Recent Task For...

Страница 11: ...ur detector they must be paired with the Android device that you use to operate your detector via OKM Rover UC App Connect your headphones according to the following steps 1 Power on your headphones B...

Страница 12: ...12 34 ASSEMBLY PREPARATION...

Страница 13: ...D green fully charged Charging LED red charging 4 Start the OKM App on the Smartwatch and select the desired operating mode see chapter 5 OPERATING MODES on page 14 2 Release the lock by turning the g...

Страница 14: ...le Explorer List of all scans that have been stored The scan files can be viewed and analy zed directly on the Smartwatch as well as transferred to a computer Settings Adjust general settings like lan...

Страница 15: ...ting 1 After clicking on the icon the Rover UC App will start the calibration 2 Rotate very slowly around your own axis approx 16s for a complete 360 rotation while the Calibrating screen is visible 3...

Страница 16: ...for fast scans Field Length Auto Impulse Mode Automatic Scan Mode Parallel 2 Select Customized to adjust the parameters individually 3 Choose the Field Length Auto Determine the length by pressing th...

Страница 17: ...can Mode to determine how to walk over the scan field while scanning Parallel Scan all lines in the same direction Zigzag Scan all scan lines in zigzag style For further information please continue wi...

Страница 18: ...gth Auto First press the Trigger to start your measurement Then take a step forward and press the Trigger again to measure the next impulse Continue in this way until you have reached the end of the f...

Страница 19: ...e Step to the left again and scan the next line Repeat this until you reached the last scan line Read more about the scanning procedure in the 3D Ground Scan Guide see infobox on page 33 After finishi...

Страница 20: ...e to scan in detail The less metals near to the surface the better your result in the operating mode 3D Ground Scan Moreover Magnetometer can be used to pinpoint objects during excavation If you have...

Страница 21: ...t move the probe or your signal becomes unstable while scanning Press to perform a Ground Balance Please note that the Magnetometer can also react on metallic trash or contamination laying on the surf...

Страница 22: ...al to the ground DO NOT turn swing or pivot the probe 1 Power on the detector and the Smartwatch Start the Rover UC App and select the operating mode Pinpointer 2 The Bluetooth connection to the detec...

Страница 23: ...tic metal like iron includes a positive red and a negative blue amplitude When looking closely you can see even 2 ferromagnetic signatures The first signature starts with a positive amplitude and the...

Страница 24: ...pressing Confirm by pressing or cancel with 1 Power on the detector and the Smartwatch Start the Rover UC App and select File Explorer 3 Open your scan for further analysis by tapping on the desired s...

Страница 25: ...pective View by tapping on or rotate and scale individually with intuitive finger gestures pinch drag 5 Replay your measurement by tapping on 6 The replay will show you the complete scan generated lin...

Страница 26: ...Deutsch DE EL English EN Espa ol ES FA Fran ais FR Italiano IT JA Polski PL RU T rk e TR ZH 5 6 2 Sound Toggle between ON and OFF The operating modes 3D Ground Scan and Magnetometer provide an acoust...

Страница 27: ...ed with your scan file for fur ther analysis and documentation in the Visualizer 3D Studio software If you do not want to log the GPS location you can turn off GPS completely 5 6 5 App Theme Toggle be...

Страница 28: ...nfi gured on the included Android device Activation may be necessary if you want to use your own Android device if you want to add further Android devices if you need to reset the pre configured devic...

Страница 29: ...ion you will see the message No new update available Confirm with Otherwise download and install the new update 5 7 INFORMATION This section shows information concerning the detector App Version Teles...

Страница 30: ...UC App When pairing Bluetooth for the first time proceed with the following steps on the notebook Click on and open Settings Devices 3 1 Power on the Smartwatch Start the Rover UC App and select File...

Страница 31: ...firm the PIN 1 Click Pair on the Smartwatch 2 Click Connect in the Windows dialog Confirm with click on Done Scroll down in the dialog window and select More Bluetooth options Make sure your device is...

Страница 32: ...en pairing the Rover UC App for the first time please make sure you have processed the steps in section 6 1 PAIRING BLUETOOTH on page 30 1 Power on the Smartwatch Start the Rover UC App and select Fil...

Страница 33: ...all if you want to delete all transferred scan files from the device after transfer Confirm with OK to finish the import For more information on handling your detector optimizing 3D Ground Scans and c...

Страница 34: ...Altenburg Germany we are developing and manufacturing geophysical detectors since 1998 Our unique detection technology helps to visualize buried objects and structures OKM GERMAN DETECTORS 49 3447 499...

Отзывы: