Page: 51
Service Guide OL830
Chapter 3 Maintenance & Disassembly
3.3.05 Resetting the Fuser Counter
After replacing the Fuser Unit, reset the fuser counter. Follow the procedure listed below.
1. Power ON the printer while pressing Switch 1 on the Engine Control board. The LED
will
flash continuously, indicating that the printer is in Parameter 1 of the
maintenance mode.
The Fuser Counter value is found in Parameter 3.
2. Press Switch 1 two times to access Parameter 3. The LED will flash three times,
indicating Parameter 3 has been selected.
3. Press Switch 1 once for five seconds. The contents of the Parameter 3 register will be
displayed.
4. Press Switch 1 once for five seconds to reset the fuser counter to zero.
5. To end the adjustment, press Switch 1 once for five seconds. The LED will flash three
times, indicating Parameter 3.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)