![Oilon RE 35 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/oilon/re-35/re-35_installation-and-operation-manual_3626590043.webp)
RE01 1445EN
41 (67)
1. To access the menu system, press
OK
.
A menu list opens on the screen.
2. Select
Domestic hot water
and press
OK
.
A list of available operating lines opens on the screen.
3. Select the
1610: Nominal setpoint
operating line and press
OK
.
4. Set the correct value and press
OK
.
4.7. Operating lines
The most commonly used operating lines in the control system are listed in the
following tables.
Time and date
Operating line number
Function
1
Hours/minutes
Set clock time.
2
Day/month
Set date.
3
Year
Set year.
User functions
Operating line number
Function
20
Language
Select the control system language.
Wireless remote control (optional extra)
Operating line number
Function
120
Connection
121
Test mode
Heating circuit 1 / Heating circuit 2
Operating line number
(Heating circuit 1 /
heating circuit 2)
Function
710 / 1010
Comfort setpoint
Set room temperature that heating circuit must reach in
comfort mode.
712 / 1012
Reduced setpoint
Set room temperature that heating circuit must reach in
reduced mode.
720 / 1020
Heating curve slope
See section
Configuring heating curve
.
Содержание RE 35
Страница 2: ......
Страница 58: ...56 67 RE01 1445EN Wilo Stratos Para 25 1 12 WSP01 ver 1...
Страница 59: ...RE01 1445EN 57 67 Wilo Stratos 40 1 12 WSP02a ver 1 WSP02b ver 1...
Страница 60: ...58 67 RE01 1445EN Wilo IPL 40 115 0 55 2 WIPL03 ver 1...
Страница 61: ...RE01 1445EN 59 67 Wilo IPL 50 115 0 75 2 WIPL02 ver 1...
Страница 62: ...60 67 RE01 1445EN Wilo IPL 50 120 1 5 2 and Wilo IPL 50 130 2 2 2 WIPL01 ver 1...
Страница 63: ...RE01 1445EN 61 67 Wilo Stratos Para 25 1 7 WSP03 ver 1...
Страница 70: ...68 67 RE01 1445EN...
Страница 71: ......
Страница 72: ...Tarmontie 4 FI 15860 HOLLOLA FINLAND Tel 358 3 85 761 Fax 358 3 857 6239 Email info oilon com www oilon com...