2.7 Connecting a second scale for piece counting
The RS connector(s) on the rear of the scale can also be used to connect
2 scales, together for a counting system. Use the scale - to - scale cable
listed in the accessory section.
Connect the cable between the scales.
The host scale (scale 1) must be a Ranger Count. In the RS menu of the
host MODE should be set to:
REF
2
If remote scale is used for average
piece weight reference.
BULK
2
If remote scale will be the bulk counting
scale.
The remote Ranger Scale can be a Ranger Count or Ranger simple
weighing. The remote scale should be set to DIALOG in the Mode sub
menu.