62
14.3 Periodic manintenace
Clean the spouts and suction tubes of every bottle position for every
10 bottles consumed and no later than 20 days of operation, coinciding
with the wine bottle running out in that position. Perform the cleaning
with suitable detergents for food-grade equipment and wine, usually
citric acid.
It is a good idea to perform a cleaning before inserting a new bottle.
The cleaning is done in the following way:
→
a.
Remove the bottle of wine and insert a bottle with 750ml capacity
containing a solution of water and 1 teaspoon or 20cc of cleaning
product provided by the supplier (
►
→
chap.19.1-
SaniPack MP 100 in
packets o SaniKleen 512 i512 in containers of 500ml
), with a ration of
20cc per 750ml of water.
→
b.
Dispense the solution through the tap, waiting 10 to 15 seconds
between each pour and repeat until the solution is exhausted
→
c.
Replace the bottle of cleaning solution with a 750ml bottle of
drinking water
→
d.
Dispense the entire bottle of drinking water.
→
e.
Replace the bottle of water with a bottle of wine and dispense
once to expel the last bit of water left in the suction tube.
Manual of Use
63
14.4 Extraordinary maintenance
Extraordinary cleaning should be done every 6 months for a perfectly
sanitized dispenser, using a disinfectant cleaner specific for enological
use and in the doses provided by the manufacturer. An optimal time
for such cleaning is during the changing of the bottles.
The procedure is as follows:
→
a.
Replace the bottle of wine with a 750ml bottle containing a
solution of water and detergent to the extent provided by the supplier
(
►
→
chap.19.2-
SaniKleen 512
).
→
b.
Dispense the solution through the tap, waiting 10 to 15 seconds
between each pour and repeat until the solution is exhausted.
→
c.
Remove the bottle of wine and insert a bottle with 750ml capacity
containing a solution of water and 30cc of cleaning product provided
by the supplier (
►
→
chap.21.2-
SaniKleen 512
),with a ration of 30cc per
750ml of water.
→
d.
Dispense the entire bottle of cleaning solution.
→
e.
Replace the bottle of cleaning solution with a 750ml bottle of
drinking water
→
f.
Dispense the entire bottle of drinking water.
→
g.
Replace the bottle of water with a bottle of wine and dispense
once to expel the last bit of water left in the suction tube.
PERFORM AN INTENSE CLEANING BEFORE LEAVING
THE DISPENSER NOT OPERATING FOR A PERIOD OF
MORE THAN 3 DAYS.
PLEASE NOTE THAT THE USE OF SWEET OR
PARTICULARLY AGED WINES MAY CAUSE THE
FORMATION OF DEPOSITS IN VARIOUS DUCTS,
INTENSIFY THE CLEANING IN THIS CASE.
►
→
67
Officine Gullo
Содержание WND 040
Страница 1: ...INSTRUCTIONS for installation and use WND 040 WINE DISPENSER FOR RESIDENTIAL AND PROFESSIONAL USE...
Страница 31: ...Manual of Use 27 31 Officine Gullo...
Страница 43: ...Manual of Use 39 Number Function 1 2 3 bottle pad spacer piston head 43 Officine Gullo...
Страница 48: ...44 W P O 17 2 C W G OK C C 17 2 C P Waiting load wine P fig 3 fig 2 fig 1 Officine Gullo 48...