41
Technical data
4flex
Dimensions per tube (length x width x height) [mm]
1955x70.9x70.9
Weight per tube (kg)
2.13
Volume per tube (l)
0.05
Max. field size (m
2
)
150 tubes = 21 m
2
( gross) /
15 m
2
(absorption area)
Max. operating pressure (bar)
6
Min. slope (°)
20
Max. slope (°)
90
Max load (kN/m
2
) (DIN 1055-5)
2.5
Heat transfer medium
Shut-off valve
Flow rate adjustment
18.0
OEG Solarflüssigkeit SFS
Open Closed
Technical data
4flex
19.0
Only run the pump when the system is filled, dry running will destroy the pump. The
recommended flow rate for systems up to 12 m² is 1 l per minute per square meter (m²)
absorber surface (10 tubes = 1 m²).
1. Set the pump to low speed and switch it on manually using the controller
(see the following paragraph).
2. If the flow is higher than required set the flow meter to the required flow rate by
adjusting the shut-off valve using a screw driver (as shown in the drawing) whilst
the pump is running. Repeat this step until the value reaches the required flow rate.
3. Stop the pump.
OEG – Solar and storage technology
4flex
®
tube collectors
GB