37
4flex connection set
14.0
OEG – Solar and storage technology
4flex
®
tube collectors
GB
Return connection (cold)
1. Assemble the return connection
(plug A, T-connection G & breather valve E)
2. Untighten the screw at the top of the outer
tube and open the lid
Flow connection (hot)
1. Assemble the return connection
(sleeve connection B, T-connection,
G and temperature sensor holder H)
2. Remove the clip from the sleeve end
of the collector
3. Rubber seal C must only be used
for tubes with direct flow and can
be disposed of
4. Lock the sleeve connector B in
position by using the clip
Important!
The collector sensor must be installed
at the flow side (hot) of the collector.
5. Ensure that the pins of clip F push through so
that the ends are visible
6. Fill in the label (I) and stick it on
7. Close the lid and secure it with a screw
Can be
disposed of
Number of tubes
F
I
A
E
G
B
G
H
For systems with direct flow only
Can be disposed of
3. Rubber seal D must only be used for tubes
with direct flow and can be disposed of
4. Lock the plug-in connector A in position
by using clip F
Components:
Can be
disposed of
C