PROPLUS 4.0 OPERATING MANUAL
© Pelagic, 2019
Doc. No. 12-5669-r01 (1/18/19)
DELAYED VIOLATION 1
If you remain shallower than a Deco Stop Depth for more than 5 minutes, operation will enter Delayed Violation 1* which is a continuation of
Conditional Violation with penalty time still being added. Again, the audible alarm will sound and the full Tissue Loading Bar Graph will flash until it
is silenced.
*The difference is that 5 minutes after surfacing from the dive, operation will now enter Violation Gauge Mode.
• Down arrow and DOWN message flashing in place of gas pressure during audible alarm.
• If the Delayed Violation 1 status is ignored, the ProPlus 4.0 will enter Delayed Violation 1 Surface mode for 5 minutes upon surfacing from the
dive. After 5 minutes on the surface in DV1 mode, the unit will enter VGM (Violation Gauge Mode).
Down Arrow
flashing
flashing
DELAYED VIOLATION 2
If the calculated Decompression obligation requires a Stop Depth between 60 ft (18 m) and 70 ft (21 m), operation will enter Delayed Violation 2.
The audible alarm will sound. Additionally, the full Tissue Loading Bar Graph will flash for 10 seconds. After 5 minutes on the surface following a
dive in which DV2 was entered, operation is to enter VGM.
flashing
DELAYED VIOLATION 3
If you descend deeper than the maximum functional depth*, the audible alarm will sound. Also, the message UP will flash for 10 seconds then depth
will display as dashes. Dashes will also display for NO DECO (No Decompression) time signifying that you are too deep.
* The maximum functional depth (Dive/Gauge = 330 ft / 100 m) is the depth at which the ProPlus 4.0 can properly perform calculations or provide accurate display information.
Upon ascending above the maximum functional depth, current depth will be restored. However, the log for that dive will display dashes for max
depth and the ProPlus 4.0 will enter Violation Gauge Mode 5 minutes after surfacing.
Содержание Proplus 4.0
Страница 5: ...5 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GETTING STARTED...
Страница 10: ...10 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 DIVE FEATURES...
Страница 15: ...15 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM SURFACE MODE...
Страница 28: ...28 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM DIVE MODE...
Страница 37: ...37 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GAUGE MODE...
Страница 39: ...39 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 REFERENCE...
Страница 43: ...43 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 TECHNICAL DATA...