12
PROPLUS 4.0 OPERATING MANUAL
© Pelagic, 2019
Doc. No. 12-5669-r01 (1/18/19)
VARIABLE ASCENT RATE INDICATOR
The VARI (Variable Ascent Rate Indicator) Bar Graph provides a visual representation of ascent speed (i.e., an ascent speedometer). When the
ascent is faster than the recommended 30 fpm (9 mpm), the bar graph will flash red until the ascent is slowed.
# OF SEGMENTS
ASCENT RATE,
FPM (MPM)
0
0 - 10 (0 - 3)
1
11 - 15 (3.1 - 4.5)
2
16 - 20 (4.6 - 6)
3
21 - 25 (6.1 - 7.5)
4
26 - 30 (7.6 - 9)
5
> 30 (> 9)
TISSUE LOADING BAR GRAPH
The Tissue Loading Bar Graph represents your relative No Decompression or Decompression status. The first four segments represent No Decompres
-
sion status and the fifth indicates a Decompression condition. As your Depth and Elapsed Dive Time increase segments are added. As you ascend
segments recede, indicating that additional No Deco (decompression) time is available. The ProPlus 4.0 monitors twelve different nitrogen compart-
ments simultaneously and the N2 Bar Graph displays the one that is in control of your dive at any given time.
DUAL ALGORITHM
®
The ProPlus 4.0 is configured with 2 algorithms which allows you to choose which set of NDLs (No Decompression Limits) will be used for nitrogen/
oxygen calculations and displays relating to Plan Mode and DTR (Dive Time Remaining) for NORM dives.
You can select DSAT or Z+ prior to new dives. Also, the selection can be changed after dives once Desaturation Time decreases to 0:00, otherwise
the selection will lock in for 24 hours after the last dive.
DSAT was the original standard used by Oceanic in all of its dive computers until the dual function was implemented several years ago. It features
NDLs that are based on exposures and test data which also formed validation for the PADI RDP. It imposes restrictions for repetitive Decompression
dives which are considered more risky than general No Deco dives.
Z+ (the Pelagic Z+ algorithm) performance is based on Buhlmann ZHL-16c. It features NDLs that are considerably more conservative than the DSAT
version especially at shallower depths.
To create even greater margins of safety with respect to decompression, a Conservative Factor as well as Deep and Safety Stops are available and
can be activated for NORM No Decompression dives.
CONSERVATIVE FACTOR
When the CF (Conservative Factor) is set On, the dive time remaining, No Decompression/Oxygen Time Remaining, which are based on the algo
-
rithm and used for N
2
/O
2
calculations and displays relating to Plan Mode, will be reduced to the values available at the altitude level that is 3,000 ft
(915 m) higher than the actual altitude at activation. Refer to the charts in the back of this manual for dive times.
DEEP STOP
When the DS (Deep Stop) selection is set ON, it will trigger after descending deeper than 80 ft (24 m). The ProPlus 4.0 then calculates (continually
updating) a Stop Depth equal to ½ the Max Depth.
NOTE: The Deep Stop feature only works in Norm mode while within No Decompression times.
• While 10 ft (3 m) deeper than the calculated Deep Stop, you will be able to access a Deep Stop Preview screen that will display the current calcu-
lated Deep Stop Depth/Time.
• Upon initial ascent to within 10 ft (3 m) below the calculated Stop Depth, a Deep Stop screen displaying a Stop Depth at ½ the Max Depth will
appear with a countdown timer beginning at 2:00 (min:sec) and counting down to 0:00. If you descend 10 ft (3 m) below, or ascend 10 ft (3 m)
above, the calculated Stop Depth for 10 seconds during the countdown, the No Decompression Main will replace the Deep Stop Main display
and the Deep Stop feature will be disabled for the remainder of that dive. There is no penalty if the Deep Stop is ignored.
• In the event that you enter Decompression, exceed 190 ft (57 m), or a High O2 SAT (Oxygen Saturation) condition, ≥ 80%, occurs, the Deep
Stop will be disabled for the remainder of that dive.
• The Deep Stop is disabled during a High PO2 Alarm condition, ≥ set point.
VARI Triggered
flashing
Содержание Proplus 4.0
Страница 5: ...5 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GETTING STARTED...
Страница 10: ...10 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 DIVE FEATURES...
Страница 15: ...15 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM SURFACE MODE...
Страница 28: ...28 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM DIVE MODE...
Страница 37: ...37 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GAUGE MODE...
Страница 39: ...39 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 REFERENCE...
Страница 43: ...43 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 TECHNICAL DATA...