PROPLUS 4.0 OPERATING MANUAL

© Pelagic, 2019

Doc. No. 12-5669-r01 (1/18/19)

PROPLUS 4.0

DIVE COMPUTER

OPERATING MANUAL

Содержание Proplus 4.0

Страница 1: ...1 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 PROPLUS 4 0 DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...S 23 1 WATER TYPE 23 2 UNITS 23 3 DEEP STOP 24 4 SAFETY STOP 24 5 ALGORITHM 24 6 CONSERVATIVE FACTOR 25 7 GLO BACKLIGHT DURATION 25 8 SAMPLE RATE 25 9 BLUETOOTH 26 SET TIME 26 SET MODE 27 HISTORY 27 S...

Страница 3: ...Loading Bar Graph TLBG Pre Dive Planning Sequence PDPS OceanLog and Dual Algorithm are all registered and unregistered trademarks trade names and service marks of Pelagic All rights are reserved PATE...

Страница 4: ...4 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 Welcome to OCEANIC and THANK YOU for choosing the ProPlus 4 0...

Страница 5: ...5 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GETTING STARTED...

Страница 6: ...t is your preference Disabling the H2O ACT feature is described in the Dive Surface Mode chapter p 26 Upon activation the unit will enter a Diagnostic Mode The ProPlus 4 0 checks the display and volta...

Страница 7: ...n 7 Tissue Loading Bar Graph 8 Log 9 History 10 Surface Time 11 Time To Fly 12 Oxygen Saturation 13 Variable Ascent Rate Indicator 14 Algorithm 15 Gas 16 Value is Maximum 17 Safety Stop 18 Descend Asc...

Страница 8: ...ey are also used to enter settings activate the backlight and acknowl edge the audible alarm Throughout this manual they will be referred to as the ADV and SEL buttons Pressing different combinations...

Страница 9: ...ens to advance or step through menus to toggle or change setpoints SEL ADV to scroll quickly changing setpoints to scroll quickly through menu lead in screens selections SEL ADV to select access step...

Страница 10: ...10 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 DIVE FEATURES...

Страница 11: ...rol shifts to slower compartments This is a feature of the decompression model that is the basis for multilevel diving one of the most important advantages that Oceanic dive computers offer O2 MIN OXY...

Страница 12: ...elagic Z algorithm performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative than the DSAT version especially at shallower depths To create even greater margins...

Страница 13: ...r Decompression during the dive complete the Decompression obligation then descend below 30 ft 9 m the Safety Stop Main will appear again upon ascent to within 5 ft 1 5 m deeper than the Safety Stop d...

Страница 14: ...following situations shall activate the Alarm 1 beep per sec for 10 sec Conditional Violation Delayed Violations 1 2 3 Ascent Rate too fast full bar graph PO2 increases to 20 Alarm Set Point and at t...

Страница 15: ...15 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM SURFACE MODE...

Страница 16: ...ions Some screens simply display data whereas the other screens are lead ins to sub menus and settings Press the SEL button to choose menus or options from the Main Menu when available All Main Menu s...

Страница 17: ...from 23 50 to 0 00 hr min 10 minutes after surfacing from a dive The SAT Desat counter shall provide calculated time for Tissue Desatuation at sea level taking into consideration the CF Conservative F...

Страница 18: ...ive is activated in either Norm or Gauge mode After the post dive 24 hour period has elapsed and the unit shuts off the first dive of the next activation period will be recorded as dive 1 In the event...

Страница 19: ...ption will not be displayed in the Set Gas menu until 24 hours elapse after the last dive If subsequent Air dives are made during this period an FO2 value of 21 should be chosen NOTE When FO2 is set f...

Страница 20: ...OFF or ON SET ALARMS Within this submenu you can customize the following seven alarm settings Within this menu you can customize the following seven alarm settings SEL ADV next item in Main Menu acces...

Страница 21: ...redetermined amount of dive time SEL ADV toggle setting save setting proceed to Set TLBG Alarm if ON or OFF to Set EDT Alarm if SET Choose OFF ON or SET flashing OFF ON or SET SEL ADV toggle setting s...

Страница 22: ...may choose from OFF or 1000 to 3000 PSI 70 to 205 BAR in increments of 250 PSI 5 BAR SEL ADV toggle setting save setting proceed to Set End Alarm if ON or OFF to Set Turn Alarm if SET Choose OFF ON or...

Страница 23: ...next item in Main Menu access Set Utilities Menu 1 WATER TYPE The Water Type feature allows you to set SALT or FRESH water environment for accurate depth calculations SEL ADV toggle setting save sett...

Страница 24: ...available 3 or 5 min Safety Stop at depths of 10 15 or 20 ft or 3 4 5 or 6 m SEL ADV toggle setting Set Safety Stop SEL ADV toggle setting Set Stop Time or 5 00 min sec save setting SEL ADV toggle set...

Страница 25: ...ory becomes full The ProPlus 4 0 Log and Download data is stored separately in different partitions of the memory The Log only stores a short sum mary of each dive Alternately the Download function st...

Страница 26: ...d off or a dive is started The ProPlus 4 0 returns to sniffing mode when the ProPlus 4 0 returns to Surface Mode after a dive or a but ton is pushed to wake the computer from Sleep Mode on the surface...

Страница 27: ...ed water temperature deepest recorded dive longest recorded dive SN SERIAL NUMBER Information displayed on the Serial Number screen should be recorded and kept with your sales receipt it will be requi...

Страница 28: ...28 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM DIVE MODE...

Страница 29: ...yed may change This is to indicate a safety recommendation warning or alarm The following information in this chapter demonstrates and describes an uneventful dive in terms of safety Alarms are descri...

Страница 30: ...00 min sec as long as you stay within 3 m 10 ft above or below the stop While Deep Stop Main is displayed you may access Alt displays by pressing the ADV button to cycle through them They are similar...

Страница 31: ...ernationally recognized training agency Overview All dives begin with gas 1 The GAS defaults to 1 after 10 minutes on the surface Gases cannot be switched while in surface mode The Gas Switch Menu can...

Страница 32: ...ECOMPRESSION STOP MAIN Decompression deco Stop Main will display upon ascending to within 10 ft 3 m below the Deco Stop depth The Full Stop icon both Arrows with Stop Bar will be displayed solid While...

Страница 33: ...lashing DELAYED VIOLATION 2 If the calculated Decompression obligation requires a Stop Depth between 60 ft 18 m and 70 ft 21 m operation will enter Delayed Violation 2 The audible alarm will sound Add...

Страница 34: ...VIO violation is to flash for 10 minutes then it will alternate with NOR Norm or GAU Gauge until 24 hours elapse with no dives During that 24 hours VGM lockout does not allow access to the Set Gas Pla...

Страница 35: ...saturation reaches the Warning Level the audible alarm sounds and the O2 oxygen saturation value will flash in place of Depth Depth will be restored when the audible alarm is silenced flashing ALARM I...

Страница 36: ...ue will flash in place of Deco Stop Time Upon silencing Current Depth is to be restored the graphics UP and O2 are to alternate and the Up Arrow is to flash until on the surface ALARM ON SURFACE If O2...

Страница 37: ...37 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GAUGE MODE...

Страница 38: ...Main Menu when available MAIN MENU ALT 1 Last Dive Max Depth Dive Time ALT 2 Elevation Time Temperature FLY LOG SET ALARMS SET UTIL SET TIME SEL MODE HISTORY SERIAL NUMBER Return to Home Menu SEL ADV...

Страница 39: ...39 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 REFERENCE...

Страница 40: ...tight integrity are not covered under the terms of the 2 year limited warranty To Obtain Service Take your ProPlus 4 0 to an Authorized Oceanic Dealer or send it to the nearest Oceanic Regional Facil...

Страница 41: ...th fresh water and allow to dry overnight or blow dry with a hair dryer set at no heat Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing Inspect the Bu...

Страница 42: ...Two readings are taken the second reading 5 seconds after the first The readings must be within 1 foot 30 cm of each other to record that ambient pressure as the current Altitude No adjustments are ma...

Страница 43: ...43 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 TECHNICAL DATA...

Страница 44: ...0 05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0...

Страница 45: ...0 03 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526...

Страница 46: ...Gauge displays Dives 1 to 24 Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores max 24 entries per day 99 entries in memory for viewing After 24 dives in one day or 99 dive...

Страница 47: ...after the dive Surface Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Points Air 21 to 100 1 PO2 Value 0 00 to 5 00 ATA 01 ATA O2 Saturation...

Страница 48: ...time FPM Feet Per Minute FT Feet depth GTR Gas Time Remaining HR Hour M Meters depth MAX Maximum M D D M Month Day Day Month MIN min Minutes time MPM Meters Per Minute NDC No Deco DTR NDL No Deco Limi...

Страница 49: ...ase ___________________________________________________________________________________________________ Purchased from _________________________________________________________________________________...

Страница 50: ...50 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 ProPlus 4 0 DIVE COMPUTER OPERATING MANUAL...