Oceanic Safety Systems PROGRAMMABLE SUBMERSIBLE LIFE VEST Скачать руководство пользователя страница 20

20

20

Programmable, Submersible Live Vest User Manual  copyright Oceanic Safety Systems LLC., 2014

MENU SEQUENCE:

BAtt

AUtO

Sub

ScbA

dELy

d-000

t-0:00

LOn

Shows the battery level. Do not use when the level is LO in normal climates, 

or below 50%

in freezing conditions.

In this Automatic mode, the vest will inflate immediately when going under water. This mode
emulates the typical auto inflating life vest, which inflates upon sinking into the water.
However, our product is immune to rain or heavy wave splashes.

In this submersion mode, the vest will inflate when 

EITHER 

the time trigger 

or 

depth trigger

is exceeded. Trigger timing does not start until submerged deeper than one meter. Use this
mode for protection from a deep fall into the water, for example from a ship, helicopter, or
parachute. If you sink too deep or for too long, the vest inflates.

In Scuba mode, the vest will inflate ONLY when trigger depth is exceeded—trigger time is
ignored. Typically used for shallow water re-breather operations where the user wants
protection from sinking to unsafe depths.

In Delay mode, the vest will inflate when the in-water trigger time is exceeded, even in water
shallower than 1 meter. Use this mode when temporary falling into the water can be
expected, and where self-rescue is preferred over immediate vest inflation, for example
crossing a river, swamp, or falling off a zodiac. In each case inflation is delayed allowing
you time to recover without unwanted inflation.

Set the trigger depth here in meters—maximum 100 meters. Hold down the set button to
advance numbers rapidly back to 0.

Set the trigger time here in minutes and seconds—maximum 9 minutes 59 seconds. Hold
down the set button to advance numbers rapidly back to 0.

Sets the 

ON

 light to on or off. By pressing the set button, you toggle between LOn (when the

green light blinks every 2 seconds informing the user the unit is on) and LOFF when the
green light is off for stealth operations. Note, even if the green blinking light is off, you can
press either the remote button, or the mode button on the actuator to tell if the unit is on.

Содержание PROGRAMMABLE SUBMERSIBLE LIFE VEST

Страница 1: ...N 6 IV HAVING SUFFICIENT CO2 IS ESSENTIAL 11 III INTRODUCTION 11 V PSLV COMPONENTS 13 VI PSLV COMPONENTS 14 VII TO PUT ON THE OCEANIC VEST 16 VIII FEATURES AND OPERATION 17 IX PREPARING THE ACTUATOR F...

Страница 2: ...RAGREEMENTAND WARRANTY AGREEMENT IS AN AGREEMENT BETWEEN YOUAND OSS YOUR USE OF THE PSLV IS SUBJECT TO THE TERMSAND CONDITIONS SET OUT IN THISAGREEMENT THIS AGREEMENT ALSO SETS OUT OSS S WARRANTY OF T...

Страница 3: ...ll damage the accessories and or the PSLV and will also void the Warranty Warranty coverage on your PSLV covers the product for 5 years subject to the conditions listed above and utilizes a prorated r...

Страница 4: ...and the condition of the parts as determined solely by OSS Pro rated value for Vest Soft Parts i Like new and less than 1 year old OSS pays 100 customer pays 0 ii Slightly used and less than 2 years o...

Страница 5: ...SS OF WHETHER OR NOT THE PSLV FUNCTIONED PROPERLY OR WAS DEFECTIVE INANYWAY YOU HEREBY IRREVOCABLY WAIVEAND RELEASEANDAGREE TO INDEMNIFY OSS ITS OWNERS MANAGERS PARTNERS AGENTS REPRESENTATIVES HEIRS S...

Страница 6: ...orrectly Cautions indicate any situation or technique that will result in potential damage to the PSLV or render the PSLV unsafe if instructions are not followed correctly Notes are used to emphasize...

Страница 7: ...pushed in DISCARD IMMEDIATELY Every CO2 cylinders has a Minimum gross weight marked on the side of the cylinder This marking is the sum of the empty steel cylinderAND the weight of CO2 that is suppos...

Страница 8: ...th by the user Caution In the event the battery leaks and the fluid gets into one s eye do not rub the eye Flush for 15 minutes with water and immediately seek medical attention If left untreated the...

Страница 9: ...y charge Of course the day before a dive trip always fully charge the battery The battery typically has a lifespan of between 300 and 500 cycles under normal usage and operating conditions Using the P...

Страница 10: ...eplace the charge plug or the unit will flood Take care not to strip the threads Removing the charger from the wall socket but leaving it attached to the actuator drains the battery DO Store battery w...

Страница 11: ...meters It is important to understand that in submersion dive Sub mode the PSLV will not start counting time and depth until the unit is at least 1 meter under the water Setting the unit in Submersion...

Страница 12: ...eights together and divide by two 38 38 2 38 to arrive at the depth providing 8 kilos 18 pounds of lift For equal weight cylinders use the weight of one cylinder as the maximum depth in meters to prov...

Страница 13: ...TTONS LEDs LCD SCREEN SHOWING DEPTH TRIGGER CHARGING PORT PLUG CORD FOR MANUAL PULLINFLATION COMPRESSION SPRING CAP ACTUATOR FRONT CONNECTION TO INFLATION BLADDER WIRE TO REMOTE COMMUNICATOR ACTUATOR...

Страница 14: ...t the button which informs him that the unit is on and if the light is blinking tells him that the unit is set to Immersion auto mode When the light is steady the unit is in Submersion dive mode or SC...

Страница 15: ...he end and blow When not in use the valve retainer should be screwed closed to prevent accidental opening of the valve PULLING THE OPV OVER PRESSURE VALVE OPV ORAL INFLATION TUBE OPEN CLOSED SPACE SPA...

Страница 16: ...right Oceanic Safety Systems LLC 2014 Put your arms through the arm holes shrug the vest collar up to your neck and connect the two J hooks in the front into molyweave See this Youtube https www youtu...

Страница 17: ...to air embolism or decompression sickness the bends Use this mode only after consultation with your dive safety officer or independent scuba instructor You decide how to program your PSLV You have th...

Страница 18: ...staying down too long OR going too deep will fire the vest Regardless of the depth once you exceed the trigger time the vest fires Vest fires ONLY when the trigger depth is exceeded Diver may stay su...

Страница 19: ...ward movement and then blow into the hose while at the same time pressing against the spring loaded valve DESCRIPTION OF MENU SCREENS AND SETTING OPTIONS Use the Mode button the large button to cycle...

Страница 20: ...ically used for shallow water re breather operations where the user wants protection from sinking to unsafe depths In Delay mode the vest will inflate when the in water trigger time is exceeded even i...

Страница 21: ...e Remote switches modes OVER WATER TRANSPORT Immediate Inflation Delayed Inflation Time only Time and Depth use dELy use Sub use AUto 1 meter only IN WATER SWIMMING Swimmers use Sub 10 sec 1 meter UND...

Страница 22: ...to its bladder or actuator until it has received a complete inspection and service from OSS Use the Inspection Checklist and tests the checklist is sewn into the back of your vest PRE USE CHECKLIST Tu...

Страница 23: ...ger is cocked You can see and hear when this occurs When the trigger is loaded you must screw down the cap until the green band appears as shown below The actuator is not properly loaded unless the gr...

Страница 24: ...t Oceanic Safety Systems LLC 2014 VISUAL REARMING SEQUENCE CONTINUED SCREW DOWN THE COMPRESSION TO EXPOSE THE GREEN BAND THE UNIT IS NOT COCKED IF THE GREEN BAND IS NOT VISIBLE 1 SOLID GREEN BAND EXPO...

Страница 25: ...ap green indicator and uses new cartridges Test the splash immunity of the PSLV in heavy weather While in auto mode attempt to cause the PSLV to fire by throwing buckets of water over it by standing o...

Страница 26: ...ct to use in the field be the subject Set the trigger time to 15 seconds and the depth to 3 meters and then have the operator jump into the pool and then swim back to the surface if possible the self...

Страница 27: ...lation sequence needs to be completed within 5 seconds At any time in the water or out pressing the remote button 4 times rapidly will trigger the unit to inflate Practice the Manual Inflation feature...

Страница 28: ...flotation between chambers without popping loose the other snaps gently depress the right bladder to send air to the left lapel Continue to fill the chambers until the desired flotation is achieved N...

Страница 29: ...nism Immerse the actuator making sure the spring chamber is completely immersed in one of these products Salt Away liquid and Bluethru tablets dissolved in water for at least an hour overnight will no...

Страница 30: ...you need to follow these preventative maintenance guidelines 1 Store the PSLV partially inflated away from direct sunlight and in a clean cool dry area Do not store the PSLV in an enclosed space such...

Страница 31: ...he PSLV be sure to remove all excess gas from the PSLV Long term storage You should prepare your PSLV for long term storage when you do not plan to use the unit for a month or more Remove the CO2 cyli...

Страница 32: ...ne cylinder discharges Examine cartridges after activation to make sure both are pierced A non pierced cartridge indicates the cylinder was not screwed in all the way or there is a failure in the mech...

Страница 33: ...and 158 F 8 and 70 C Because of variations in battery performance at low temperatures we recommend that you do not use the unit in freezing conditions with less than a 50 incdicated battery level INFL...

Страница 34: ...or non warranty work Our preferred payment is by Visa or MasterCard To process your order we need your account number expiration date name on the card security code and billing address You may also pr...

Страница 35: ...ou decline our service estimate or if the product is not serviceable we will return your PSLV or component ground return freight at no charge When shipping we recommend you use an insured traceable sh...

Страница 36: ...too long use Sub Mode When you fall or plunge into the water and go deeper than 1 meter the time and depth triggers become active use t 0 00 to set the maximum time under 1 meter and use d 000 for th...

Страница 37: ...use Bring along some salt remover and a small spray can of WD 40 and use them after the end of each dive This is critical for the spring chamber I WANT TO REDUCE MY TRIGGER SETTING BUT IT ONLY GOES UP...

Отзывы: