Maintenance
U20944-J-Z247-6-7600
you may open the trace files again via the TOPE subcommand. See the TRACEFILE
parameter from the SETUPcuu sublibrary member.
TLEV
Requests SPS to change the trace level being used. The trace level
controls the amount of information traced by SPS. See the TRACELEV parameter from
the SETUPcuu sublibrary member.
Is the new trace level to be used by SPS. You should specify a value
between 0 and 4. Trace level 0 means no trace. Trace level 1 is a flow trace. Trace level 2
is a flow and status trace. Trace level 3 is a flow, status and control block trace. Trace
level 4 is a flow, status, control block and data trace. The specified trace level remains
active until the next TLEV subcommand is successfully processed or the printer is stoped
and started. See the TRACELEV parameter from the SETUPcuu sublibrary member.
If you start SPS with trace level 0 or traceset (00,00,00, ...) and
PSDYNTRA (NO) you are not able to activate the trace of the PS/APA componet of SPS
via this command. On the other hand, when running with this options a smaller and
optimized version of the PS/APA driver is used.
When you specify trace level 0 in this command or in the SETUPcuu
sublibrary member SPS forces an in-storage only trace level 1 of the L
###
(base)
component of SPS.
This reduced trace has a minimum performance impact and may help
when only a dump is available to solve a problem.
TSET
Requests SPS to change the trace set being used. The trace set controls
the type of information traced by the SPS printer driver. Each driver (one for each printer
type) may use the trace set bits in a different way and its use is not documented in this
manual. A change of the trace set bits should be done only when requested from your
Océ systems representative. See the TRACESET parameter from the SETUPcuu
sublibrary member.
hhhhhhhhhhhhhhhh
Is the new trace set to be used by SPS. You should specify 16 contiguous hexadecimal
digits (0-9,A-F). The specified trace set remains active until the next TSET subcommand
is successfully processed or the printer is stoped and started. See the TRACESET
parameter from the SETUPcuu sublibrary member.
Содержание PRISMAproduction
Страница 1: ...Océ PRISMAproduction ROUTER V1 0 Reference Guide ...
Страница 50: ......
Страница 70: ......
Страница 71: ...SPS Start up Procedures U20944 J Z247 6 7600 ...
Страница 96: ...Maintenance U20944 J Z247 6 7600 ...
Страница 127: ...Messages U20944 J Z247 6 7600 Do not place the Alternate Library either in the LPA or in a STEPLIB for the application ...
Страница 128: ......
Страница 132: ...U20944 J Z247 6 7600 ...
Страница 134: ......