Installation and Customization
U20944-J-Z247-6-7600
The SPS install data sets should be protected by whatever security product the installation
uses.
DDDEF's should be defined for each of the ddnames in Table 5 on page 20. The
suggested attributes will simplify maintenance procedures. If you have run the sample job
SPSISSMP, these DDDEF's are already defined.
DATA SET
RECFM
LRECL
BLKSIZE
BLOCKS
DIR
SPS.ASPSDLIB U -
6144
900,100
42
SPS.ASPSSAMP FB 80 3120
1200,120
40
SPS.ASPSMESS VB 251
5020
50,10
5
SPS.SPSLINK U
-
6144
1800,200
16
SPS.SPSSAMP FB
80
3120
1200,120
40
SPS.SPSMESS VB
251
5020
50,10
5
Table 4: SPS Data Set Allocations