Installation and Customization
U20944-J-Z247-6-7600
found a matching group entry the IPADDR and PORTNUM are used as the target
destination. Multiple group statements can exist for a single server destination using
different selection criteria. (See ROUTER table section).
In OS/390 (MVS) a routing control file is defined per start procedure(FSS) that has a DD
statement of RTRTABDD, this file is then shared by the devices (FSAs) that run under the
control of the FSS.
Therefore to introduce changes in a routing table, the changes must be made to the table
then the FSS must be stopped and then started again.
Syntax Rules for ROUTER control table
All parameters should be written in uppercase
All parameter values should be coded in uppercase, exception to this being the TCPIP
name parameter which can be coded in mixed case.
Each parameter must be coded on a seperate line.
End a group of parameters relevant for a particular destination by a semi colon
Comments should be coded on seperate lines and must begin with /*
ROUTER controls the parameters for syntax as the print device is started, giving
messages when errors are found for KEYWORDS, PARAMETERS to keywords and also
over GROUP validity.
TCPNAME(TCPIP);
/**UNIX BOX IN COMPUTER CENTRE************************
DEST(PRISMA1)
CLASS(ABC)
FORMS(UNIX)
IPADDR(160.120.17.233)
PORTNUM(6401)
RETRYINT(20)
RETRYNUM(2)
YEAR_FORMAT(YYYY)
SEND_REC_LENGTH(YES);
Figure 13: Example Router control table.
TCPNAME
(
tcpipname)
;
Is the 1-8 character job name of the TCP/IP address
Содержание PRISMAproduction
Страница 1: ...Océ PRISMAproduction ROUTER V1 0 Reference Guide ...
Страница 50: ......
Страница 70: ......
Страница 71: ...SPS Start up Procedures U20944 J Z247 6 7600 ...
Страница 96: ...Maintenance U20944 J Z247 6 7600 ...
Страница 127: ...Messages U20944 J Z247 6 7600 Do not place the Alternate Library either in the LPA or in a STEPLIB for the application ...
Страница 128: ......
Страница 132: ...U20944 J Z247 6 7600 ...
Страница 134: ......