Maintenance
U20944-J-Z247-6-7600
The PXMIT command may be also used to obtain status information from the printer. The
following 3 subcommands are allowed:
PXMIT DEV,devname,STAT
PXMIT DEV,devname,FORM
PXMIT DEV,devname,JOBS
STAT
Requests SPS to display the printer status via message SPS0270I (main
line), the status of the jobs being printed via message SPS0270I (continuation lines) and
the status of the trace environment via message SPS0266I. Please see the description of
the mentioned messages for an explanation of the status information displayed.
FORM
Requests SPS to display the printer status via message SPS0270I (main
line) and the status of the user and real forms mounted on the printer via messages
SPS0256I. Please see the description of the mentioned messages for an explanation of
the status information displayed.
JOBS
Requests SPS to display the printer status via message SPS0270I (main
line) and the status of the jobs being printed via message SPS0270I (continuation lines).
Please see the description of the mentioned messages for an explanation of the status
information displayed.
The PXMIT command may be also used to display and change the trace environment.
The following 5 subcommands are allowed:
PXMIT DEV,devname,TDIS
PXMIT DEV,devname,TOPE
PXMIT DEV,devname,TCLO
PXMIT DEV,devname,TLEV n
PXMIT DEV,devname,TSET hhhhhhhhhhhhhhhh
TDIS
Requests SPS to display the status of the trace environment via message
SPS0266I. This message shows if the trace files are open or closed, shows the current
trace level (see TRACELEV parameter from the SETUPcuu sublibrary member) and
shows the current trace set (see TRACESET parameter from the SETUPcuu sublibrary
member).
TOPE
Requests SPS to open and start using the trace files. If the trace files are
already open this subcommand has no effect. While the trace files are open you may not
run the trace formatter program. See the TRACEFILE parameter from the SETUPcuu
sublibrary member.
TCLO
Requests SPS to close and stop using the trace files. If the trace files are
already closed this subcommand has no effect. While the trace files are closed you may
run the trace formatter program to copy or format the trace records. After the formatter run
Содержание PRISMAproduction
Страница 1: ...Océ PRISMAproduction ROUTER V1 0 Reference Guide ...
Страница 50: ......
Страница 70: ......
Страница 71: ...SPS Start up Procedures U20944 J Z247 6 7600 ...
Страница 96: ...Maintenance U20944 J Z247 6 7600 ...
Страница 127: ...Messages U20944 J Z247 6 7600 Do not place the Alternate Library either in the LPA or in a STEPLIB for the application ...
Страница 128: ......
Страница 132: ...U20944 J Z247 6 7600 ...
Страница 134: ......