Installation and Customization
U20944-J-Z247-6-7600
//STEP5 EXEC PGM=IEWL,REGION=512K,
// PARM='MAP,RENT,NCAL,LIST,LET,XREF,AC=0'
//SYSUT1 DD UNIT=SYSDA,SPACE=(CYL,(4,1))
//SYSPRINT DD SYSOUT=A
//SYSLMOD DD DSN=SYS1.SVCLIB,DISP=SHR
//ASPSDLIB DD DSN=SYS1.ASPSDLIB,DISP=SHR
//SYSLIN DD *
INCLUDE ASPSDLIB(IGG019WM)
ENTRY IGG019WM
NAME IGG019ZZ(R)
Figure 4: Sample JCLIN Modification for Appendage Named ZZ
Authorize SPS Libraries in the System
The SPS target load library must be authorized. SPS can be run as an authorized steplib,
as a member of LINKLST or loaded from LPA.
When run as an authorized steplib, the SPS load library name must be added to the
IEAAPF00 member of SYS1.PARMLIB.
When run as a member of linklst, the SPS load library name must be added to linklst, and
if the installation linklst is not authorized then it must also be added to IEAAPF00.
When loaded from the LPA, no special action is necessary as modules loaded from LPA
are normally authorized. Model statements for these procedures can be found in
members SPSIAPF and SPSILNK of SPS.SPSSAMP.