Safety information
147
Safety data sheet for the Océ 9400-II Printer and Scanner
©1997 Océ-Technologies B.V.
The contents of this safety data sheet are subject to the disclaimer o n page145
of this manual.
PRODUCT SAFETY DATA SHEET
Number
E-685-b-US
Date
March 1999
Model
Océ 9400/9400-II Printer - Océ 9400/9400-II Scanner
Description
Multifunction device, instant copying/printing, consisting of an electrostatic printer, console
model, plain paper, organic photoconductive drum, powder toner and a free standing
scanner, maximum original size 1020 mm x 3000 mm.
Max. process speed
3 m/min
Dimensions
Width
Printer
Scanner
1 roll
2 roll
1352 mm
1352 mm
1240 mm
Depth
918 mm
918 mm
615 mm
Height
1251 mm
1251 mm
1105 mm
Weight
149 kg
159 kg
60 kg
Voltage
115 V
115 V
Frequency
60 Hz
60 Hz
Current-rated
15 A
1,1 A
Current-max
20 A
2 A
Power consumption
1500 W at continuous operation
90 W at continuous operation
Power consumption, stand by
46 W
3,2 W
EPA Energy Star®
* Power consumption,
sleep mode
49,2 W (p scanner). Default time 1 minute.
Mains connection
Cable with plug
Safety class
I
(IEC 536) Protective earth connection
Protection class
IP 20
(IEC 529)
Sound pressure level
(at bystander/operator
position)
Stand by
In operation
Stand by
In operation
0 dB(A)
main body 51 dB(A)
0 dB(A)
main body 48 dB(A)
impulse
∆
L
i
= 2 dB(A)
impulse
∆
L
i
= 5 dB(A)
Sound power level
0 dB(A)
main body 61 dB(A)
0 dB(A)
main body 60 dB(A)
Radio interference
Complies with FCC rules and regulations, part 15 class A
Radiation
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Heat emission
Printer 1500 W, scanner 90 W at continuous operation
Ozone emission printer
0,02 mg/min at continuous operation
Room volume
Recommendation: min. 25 m
3
Room ventilation
Recommendation: min. 12,5 m
3
/h (natural ventilation)
Use simulation at random
operation
With a room volume and ventilation as recommended and a daily volume of 100 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average
0,002 mg/m
3
(0,001 ppm)
- Peak
0,008 mg/m
3
(0,004 ppm)
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone
0,04 mg/m
3
(0,02 ppm)
Consumables
Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B4 Toner (Océ Safety Data Sheet E-196)
Océ D4 Developer (Océ Safety Data Sheet E-197)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper. Ask Océ for suitable recycling
paper.
Additional safety information
The ozone ?lter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m
3
(i.e. the life of the ?lter equals that of the apparatus).
Listed according to standard
Listed according to standard
EPA MFD Compliance
UL 1950
CAN/CSA-C22.2 No. 950
Содержание 9400-I
Страница 1: ...Océ 9400 I User Manual ...
Страница 8: ...8 Océ 9400 II User Manual ...
Страница 55: ...55 Océ 9400 I User Manual Chapter 4 Copy jobs This chapter describes how to make copies ...
Страница 69: ...69 Océ 9400 I User Manual Chapter 5 Print jobs This chapter describes how to print files ...
Страница 78: ...78 Océ 9400 II User Manual ...
Страница 115: ...Advanced printer menu functions 115 Service This menu is intended only for the Océ service technician ...
Страница 116: ...116 Océ 9400 II User Manual ...
Страница 127: ...127 Océ 9400 I User Manual Appendix A Overview and tables ...
Страница 139: ...139 Océ 9400 I User Manual Appendix B Controller firmware upgrade ...
Страница 143: ...143 Océ 9400 I User Manual Appendix C Safety information ...
Страница 149: ...Safety information 149 ENERGY STAR is a U S registered mark ...
Страница 150: ...150 Océ 9400 II User Manual ...
Страница 151: ...151 Océ 9400 I User Manual Appendix D Miscellaneous ...