CASE REMOVAL FROM SKID [LEVELERS OR CASTERS] 

2.   Remove Case (With Casters) From Skid

 

A.  Place ramp up against skid (to allow case to 

smoothly slide off from skid). 

B.  Maintain support of case at all times or center 

of gravity may cause case to fall.  

C.  Unlock Casters.  Slide unit to rear of skid.  

Slide down ramp and off from skid. 

Ramp 

 

Various Types Of 

Case Shipping 

Brackets 

1.   Removing Case Shipping Brackets That Are Attached To Skid

 



Remove screws holding Case Shipping Brackets to skid. 



Remove Case Shipping Brackets from Skid. 



See illustrations below.  Note: Shipping Brackets will vary in size, shape, material and location 
depending upon case type and model. 

Support case 

while sliding 

down ramp. 

Содержание CO34R

Страница 1: ... 47 1 4 L x 33 1 4 D x 47 H Includes end panels OPEN REFRIGERATED SELF SERVICE MERCHANDISER I Oper Manuals Oasis CO34R_CO44R_20 25622 pub 888 E Porter Road Muskegon MI 49441 Phone 231 798 8888 Fax 231 798 4960 www structuralconcepts com INSTALLATION AND OPERATING MANUAL Model CO44R Optional Shelf Not on All Cases ...

Страница 2: ...ED BY STORE PERSONNEL CLEANING SCHEDULE TO BE PERFORMED BY TRAINED SERVICE PROVIDERS PREVENTIVE MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PROVIDERS TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL TROUBLESHOOTING TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY CAREL TEMPERATURE CONTROLLER PROGRAMMING THE INSTRUMENT CAREL TEMPERATURE CONTROLLER USER INTERFACE DISPLAY SUMMARY TABLE OF ALARM...

Страница 3: ...violation of applicable NEC federal state and local electrical and plumbing codes are not covered by warranty See below compliance guideline WARNINGS This sheet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS and WIRING DIAGRAMS See next page for PRECAUTIONS and WIRING DIAGRAM information WARNING Hazardous moving parts Do not operate unit with covers remove...

Страница 4: ... been treated to resist breakage and must be replaced with similarly treated lamps CAUTION PRECAUTIONS This sheet contains important precautions to prevent damage to unit or merchandise Please read carefully See previous page for specifics on OVERVIEW TYPE COMPLIANCE and WARNINGS WIRING DIAGRAM Each case has its own wiring diagram folded and in its own packet Wiring diagram placement may vary it m...

Страница 5: ...tructural Concepts at 1 800 433 9489 3 Damage Discovered After Uncrating 3rd Party Carrier Contact carrier within 10 days of delivery for their procures retain all packaging If these steps are not taken carrier may refuse your claim Prepaid and Add Contact carrier and follow same procedure as with 3rd party carrier Also contact Structural Concepts at 1 800 433 9489 within 10 days of delivery 4 Sho...

Страница 6: ... C Unlock Casters Slide unit to rear of skid Slide down ramp and off from skid Ramp Various Types Of Case Shipping Brackets 1 Removing Case Shipping Brackets That Are Attached To Skid Remove screws holding Case Shipping Brackets to skid Remove Case Shipping Brackets from Skid See illustrations below Note Shipping Brackets will vary in size shape material and location depending upon case type and m...

Страница 7: ...e case Obstruction or restriction of air can void warranty 6 Front Grille 2 Removing Shipping Screws Plastic glides are mounted to the unit base to assist in sliding the condenser out for access Remove the front grill by removing the screws located in each of the corners Remove the shipping screws located at base of condenser frame Shipping Screws 12 Front of Case Top View Side View ...

Страница 8: ... left hand side of base Replace front grille Supply power will start evaporator coil fans and the compressor motor From front of case raise deck pans and check to see that the coil fan is functioning properly Replace front grille by inserting screws in locations provided Main Power Switch Removable Front Panel Optional Shelf Not on All Cases ...

Страница 9: ...wn in illustration below First time lighting may require a short warm up period for the bulb Slightly dim or a flickering of new bulb is normal If light do not turn on see TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL section in this operating manual 9 3 Temperature Settings The case temperature is set at the factory supply air 25 F for a case temp of 41 F as determined by the case size The t...

Страница 10: ...lf straight up to separate from brackets Remove brackets Note Initially it may be necessary to remove the nylon shipping bracket retainer Pliers will be required to accomplish this task 2 Light Fixtures Light fixture is located on the top header of case Removal of lamp Rotate lamp 1 4 turn so that pins are aligned in slots and remove bulb Installation of lamp Align pins with slot Insert pins into ...

Страница 11: ... the honeycomb to allow it to be pulled out of honeycomb retainer C Pry downward and away from honeycomb retainer Clean honeycomb with warm water and soap solution Submerse if necessary Use brush to dislodge stubborn or sticky residue Dry by using vacuum s blow mode vs suction mode Honeycomb Air Diffuser Installation D Squeeze honeycomb to allow it to fit into honeycomb retainer E Carefully slide ...

Страница 12: ...ssembly or disassembly and servicing is to be accomplished by licensed refrigeration contractors only Plastic Glide Servicing refrigerant is accomplished from the rear of the case Note Condenser unit does not slide to the rear Lift front panel up and off hooks to remove Service connections are located to the left of the compressor See next page for illustrated parts breakdown of condenser unit Pla...

Страница 13: ...Compressor and Electrical Box Overflow Evap Pan Electric Coil and Electrical Box Sight Glass Filter Dryer Condensate Pan Caution Though refrigerant lines are flexible to facilitate front access maintenance do not crimp or kink copper tubing while sliding condenser unit out from under case Slide condenser unit forward approximately 12 to access components Wicking material optional may be part of ho...

Страница 14: ...s well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concepts Technical Service Department See images below for samples of both refrigerated and non refrigerated serial labels Sample Serial Label For Refrigerated Case Sample Serial Label For Non Refrigerated...

Страница 15: ... non abrasive cloth Weekly Wood Laminate and Painted Surfaces Clean with mild soap and water solution and a soft cloth Monthly Under Case Remove rear panel and or front panel Clean under case with vacuum Case Interior Daily Decks Inserts Wipe down and clean with mild soap water soft cloth Daily Shelves Shelves can be cleaned with a warm soap and water solution and soft cloth or paper towel For stu...

Страница 16: ...e pan and overflow electric coil condensate pan Use wet dry vacuum to remove all residue Use clean towel dipped in soap and water solution to wipe down all fans motor refrigeration lines cords knobs sight glass connectors and all other surfaces Wipe dry Slide back under case Replace front panel Qtly Evaporative Wicking Material Optional Wicking material if any on your hot gas loop condensate syste...

Страница 17: ...rews Slide Roll out condensing unit assembly Remove the four 4 screws holding the Clean Sweep rails intact Remove the Clean Sweep rail Wash rails brushes in hot water and mild soap solution If brushes are worn they must be replaced Call Technical Service Department to replace Toll Free number is listed at end of manual Clean Condensing Coil Use air pressure or industrial strength vacuum clean the ...

Страница 18: ...an pan Rinse thoroughly do not submerse in water Quarterly Under Case Cleaning Once refrigeration package is clear of unit vacuum under case to remove all dust and dirt that may collect under case Case Interior Quarterly Tub Coil Drain Fan Blades Motors Brackets Disconnect power from the case before cleaning the Tub Coil Fan Motor and Drain Area Remove Decking Sub Deck and Fan Shroud Use vacuum to...

Страница 19: ...t case rear near main power switch for Type of case If unable to resolve issue of water on floor contact technical service Call toll free number listed at end of manual Excessive Fan Noise Check that the case is aligned level and plumb System is not Operating Check that the utility power is on Check that the MAIN power switch is on Check the circuit breaker box for tripped circuits Digital Control...

Страница 20: ...by product or other décor Note Product displayed on Front Air Grilles will cause case to run warm and will negate warranty Condensing Unit Not Operating Check that the main power switch is turned on Check that case is on and the control display is not blank If blank call toll free number at end of manual Controller may be in defrost mode Compressor cycling on and off is a normal condition Carel Te...

Страница 21: ...ed over condensate pan or floor drain for remote units Check store conditions To prevent condensation in Type 1 environments maximum conditions are to be 55 humidity 75 Fahrenheit For Type 2 environments maximum conditions are to be 60 humidity 80 Fahrenheit See serial label at case rear near main power switch for Type of case Caution Wicking material if any on your particular hot gas loop system ...

Страница 22: ...heck that the MAIN power switch is on Check that fans are plugged in at the fan shroud Check for foreign material obstructing fan performance Check that fan blades freely rotate within fan shrouds Check that power is going to fans Check that fan wiring is connected on terminal blocks Digital Control Display Is Blank Check that the MAIN power switch is on Check the circuit breaker box for tripped c...

Страница 23: ...NGS PRECAUTIONS WIRING PLUGS section in manual for adverse conditions spacing issue parameters Check that condenser coil has been cleaned Check air return grilles for obstructions Check sight glass for flashing and or low charge Check Set Point Temperature it may be adjusted too high Condensing Unit Is Not Operating Check that the power is turned on Determine if temperature controller settings are...

Страница 24: ... timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Set Set aux Prg mute def Prg mute Set Set def Set aux aux def Set Prg mute Oper Manuals PUB Templates Carel Controller Carel Controller IR33 pub This data derived from Carel Material ir33 030220441 rel ...

Страница 25: ...eset reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 User Interface Display 25 ...

Страница 26: ...ator min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 5 Select Celsius C or Fahrenheit F flag C 0 1 26 For Case Specific Defaults See Serial Label Located Near Electrical Access On Your Case For Additional Technical Information Call Structural Concepts Technical Service Dept at 1 800 433 9489 Unit Of Measure Read And...

Страница 27: ...d by SCC as a result of or in connection with any act omission or use of the Goods by Purchaser its employees or customers or any breach of this Agreement by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative and may be exercised from time to time In a proceed...

Отзывы: