13
REFRIGERATION FUNDAMENTALS - PAGE 2 of 2
Hot Gas Condensate Unit
Assembly or disassembly and servicing must
be accomplished by licensed electrical /
refrigeration contractor.
Remove the front grille by lifting up and off.
Plastic glides are mounted to the unit base to
assist in sliding the condenser out for access.
Ensure that shipping screws have been removed.
Hot Gas
Serpentine Coil
Wicking Material
[Optional]
Compressor
and
Electrical Box
Overflow Evap. Pan
[Electric Coil] and
Electrical Box
Sight Glass
Filter Dryer
Condensate
Pan
Caution! Though refrigerant lines are flexible
to facilitate front access maintenance, do not
crimp or kink copper tubing while sliding
condenser unit out from under case!
Slide condenser unit forward approximately 12”
to access components.
Wicking material [optional] may be part of hot gas
loop serpentine coil.
After servicing or cleaning unit, carefully slide
condensing unit back under case.
Return front grille to case.
Refrigerant
Line Loop
Condenser Motor
And Fan
Refrigerant
Line Loop
Support