10
MAINTENANCE
Refrigerant lines are flexible to facilitate
maintenance. However, use caution to avoid
crimping or kinking copper tubing while
sliding condenser unit out from under case!
Plastic glides are mounted to the unit base to
assist in sliding the condenser out for access.
Remove shipping retaining screws.
Slide condenser unit forward approximately
twelve inches to access the light ballast.
Ballast is located on the left side of the
condenser in electrical box. See illustration
below left.
1. Shelf Assembly Removal
Shelf can be removed for cleaning or adjustment.
For lighted shelving, unplug the light cord.
Lift shelf straight up to separate from brackets.
Remove brackets.
Note: Initially, it may be necessary to remove the
nylon shipping bracket retainer. Pliers will be
required to accomplish this task.
2. Light Fixtures
Light fixture is located on the top header of case.
Removal of lamp:
Rotate lamp (1/4-turn) so that pins are aligned in
slots and remove bulb.
Installation of lamp:
Align pins with slot.
Insert pins into socket and rotate 1/4 turn to
secure pin contacts in socket.
3. Ballast Access
Assembly or disassembly and servicing
to be accomplished by licensed electrical
contractors only.
Remove the front grille by lifting up and off.
Evaporator
Fan
Deck Pans
Bracket
Retainers
Top Header
Caution! Do not crimp or kink
copper tubing while sliding
condenser unit out from under case!
View of Ballasts (After Removal
of Electrical Box Cover)