Oasis CO34R Скачать руководство пользователя страница 27

27 

SCC TECHNICAL SERVICE CONTACT INFORMATION & WARRANTY INFORMATION 

LIMITED WARRANTY 

 

 

 

All sales by Structural Concepts Corporation (SCC) are subject to the following limited warranty. “Goods” refers to the product or products being sold by SCC. 

 

Warranty Scope: 

Warranty is for equipment sold in the United States, Canada, Mexico and Puerto Rico.  Equipment sold elsewhere may carry modified warranty. 

 

Warranty; Remedies; Limitations

. SCC warrants that if any Goods are found by an authorized representative of SCC not to be of good material or workmanship within one   

year of the date of shipments SCC will, at its option after inspection by an authorized representative, replace any defective Good or pay the reasonable cost of replacement for 
any such defective Goods, provided that written notice of the defect is given to SCC within 30 days of the appearance of such defect. If notice is not given within such period, any 
claim for breach of warranty shall be conclusively deemed to have been waived and SCC shall not be liable under this warranty. If SCC is unable to repair or replace the defective 
Goods, SCC shall issue a credit to the Purchaser for all or part of the purchase price, as SCC shall determine.  The replacement or payment in the manner described above shall 
be the sole and exclusive remedy of Purchaser for a breach of this warranty. If any Goods are  defective or fail to conform to this warranty, SCC will furnish instructions for their 
disposition. No Goods shall be returned to SCC without its prior consent.  

 

SCC’s liability for any defect in the Goods shall not exceed the purchase price of the Goods. SCC SHALL HAVE NO LIABILITY TO PURCHASE FOR CONSEQUENTIAL      
DAMAGES OF ANY KIND WHATSOEVER, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, LOST PROFITS, OR OTHER ECONOMIC 
INJURY DUE TO ANY DEFECT IN THE GOODS OR ANY BREACH OF SCC, SCC SHALL NOT BE LIABLE TO THE PURCHASER IN TORT FOR ANY NEGLIGENT DESIGN 
OR MANUFACTURE OF THE GOODS, OR FOR THE OMISSION OF ANY WARNING THEREFROM. 

 

SCC shall have no obligation or liability under this warranty for claims arising from any other party’s (including Purchaser’s) negligence or misuse of the Goods or environmental 
conditions. This warranty does not apply to any claim or damage arising for or cause by improper storage, handling, installation, maintenance, or from fire, flood, accidents,   
structural defects, building settlement or movement, acts of God, or other causes beyond SCC’s control.  

 

Except as expressly stated herein, SCC makes no warranty, express, implied, statutory or otherwise as to any parts or goods not manufactured by SCC. SCC shall warrant such 
parts or Goods only (I) against such defects, (II) for such periods of time, and (III) with such remedies, as are expressly warranted by the manufacturer of such parts of Goods. 
Notwithstanding the foregoing, any warranty with respect to such parts of Goods and any remedies available as a result of a breach thereof shall be subject to all of the          
procedures, limitations, and exclusions set forth herein. 

 

THE WARRANTIES HEREIN ARE IN LIEU OF ALL WARRANTIES, EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. IN PARTICULAR, SCC MAKES NO WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

 

No representative, agent or dealer of SCC has authority to modify, expand, or extend this Warranty, to waive any of the limitations or exclusions, or to make any different or    
additional warranties with respect to Goods.  

 

Period of Limitations

. No claim, suit or other proceeding may be brought by Purchaser for any breach of the foregoing warranty or this Agreement by SCC or in any way arising 

out of this Agreement or relating to the Goods after one year from the date of the breach. In the interpretation of this limitation on action for a breach by SCC, it is expressly 
agreed that there are no warranties of future performance of the goods that would extend that period of limitation herein contained for bringing an action. 

 

Indemnifications

. Purchaser agrees to indemnify, hold harmless, and defend SCC if so requested, from any and all liabilities, as defined herein, suffered, or incurred by SCC as 

a result of, or in connection with, any act, omission, or use of the Goods by Purchaser, its employees or customers, or any breach of this Agreement by Purchaser.  Liabilities 
shall include all costs, claims, damages, judgments, and expenses (including reasonable attorney fees and costs). 

 

Remedies of SCC

. SCC’s rights and remedies shall be cumulative and may be exercised from time to time. In a proceeding or action relating to the breach of this Agreement by 

Purchaser, Purchaser shall reimburse SCC for reasonable costs and attorney’s fees incurred by SCC. No waiver by SCC of any breach of Purchaser shall be effective unless in 
writing nor operate as a waiver of any other breach of the same term thereafter. SCC shall not lose any right because it has not exercised it in the past. 

 

Applicable Law. This Agreement is made in Michigan and shall be governed by and interpreted according to Michigan law. Any lawsuit arising out of this Agreement or the Goods 
may be handled by a federal or state court whose district includes Muskegon County, Michigan, and Purchaser consents that such court shall have personal jurisdiction over 
Purchaser. 

 

Miscellaneous. 

If any provision of this Agreement is found to be invalid or unenforceable under any law, the provision shall be ineffective to that extent and for the duration of  

the illegality, but the remaining provisions shall be unaffected. Purchaser shall not assign any of its rights nor delegate any of this obligations under this Agreement without prior 
written of SCC. This Agreement shall be binding upon and inure to the benefit of SCC and Purchaser and each of their legal representatives, successors and assigns. 

 

SCC warrants its products to be free of defects in materials and workmanship under normal use and service for a period of one (1) year from the date of delivery. 

 

This warranty is extended only to the original purchaser for use of the Goods. It does not cover normal wear parts such as plastic tongs, tong holders, tong cables, bag holders,  
or acrylic dividers. 

 

General Conditions. 

All service labor and/or parts charges are subject to approval by SCC. Contact the Customer Service Department in writing or call 231-798-8888. 

 

All claims must contain the following information: (1) model & serial code number of equipment; (2) the date and place of installation; (3) the name and address of the agency 
which performed the installation; (4) the date of the equipment failure; and (5) a complete description of the equipment failure and all circumstances relating to that failure.  

 

Once the claim has been determined to be a true warranty claim by SCC’s Customer Service Department, the following procedure will be taken: (1) replacement parts will be sent 
at no charge from SCC on a freight prepaid basis; (2) reimbursement for service labor will be paid if the following conditions have been met - (a) prior approval of  service agency 
was awarded from the Customer Service Department; and (b) an itemized statement of all labor charges incurred is received by the Customer Service Department. The cost of 
the service labor reimbursement will be based on straight time rates and reasonable time for the repair of the defect. 

 

If problems occur with any compressor, notify SCC’s Customer Service Department immediately. Any attempt to repair or alter the unit without prior consent from the Customer 
Service Department will render any warranty claim null and void. This warranty and protection plan does not apply to any condensing unit or any part thereof which has been 
subject to accident, negligence, misuse, or abuse, or which has not been operated in accordance with the manufacturer’s recommendations or if the serial number of the unit has 
been altered, defaced, or removed. 

 

Limit of Liability. 

The limit of liability of SCC toward the exchange cost of the original condensing unit, F.O.B. SCC, Norton Shores, MI, of each motor-compressor assembly 

replaced during the warranty shall not exceed manufacturer's current established wholesaler’s exchange price and in no case shall the labor of removing or replacing the       
motor-compressor or parts thereof be the responsibility of SCC. 

STRUCTURAL CONCEPTS CORPORATION TECHNICAL SERVICE 

PHONE NUMBER: 1.800.433.9489 or For Your Master Service Agent See 

WWW.STRUCTURALCONCEPTS.COM/Contact/Master_Service_Agents.asp  

Содержание CO34R

Страница 1: ... 47 1 4 L x 33 1 4 D x 47 H Includes end panels OPEN REFRIGERATED SELF SERVICE MERCHANDISER I Oper Manuals Oasis CO34R_CO44R_20 25622 pub 888 E Porter Road Muskegon MI 49441 Phone 231 798 8888 Fax 231 798 4960 www structuralconcepts com INSTALLATION AND OPERATING MANUAL Model CO44R Optional Shelf Not on All Cases ...

Страница 2: ...ED BY STORE PERSONNEL CLEANING SCHEDULE TO BE PERFORMED BY TRAINED SERVICE PROVIDERS PREVENTIVE MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PROVIDERS TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL TROUBLESHOOTING TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY CAREL TEMPERATURE CONTROLLER PROGRAMMING THE INSTRUMENT CAREL TEMPERATURE CONTROLLER USER INTERFACE DISPLAY SUMMARY TABLE OF ALARM...

Страница 3: ...violation of applicable NEC federal state and local electrical and plumbing codes are not covered by warranty See below compliance guideline WARNINGS This sheet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS and WIRING DIAGRAMS See next page for PRECAUTIONS and WIRING DIAGRAM information WARNING Hazardous moving parts Do not operate unit with covers remove...

Страница 4: ... been treated to resist breakage and must be replaced with similarly treated lamps CAUTION PRECAUTIONS This sheet contains important precautions to prevent damage to unit or merchandise Please read carefully See previous page for specifics on OVERVIEW TYPE COMPLIANCE and WARNINGS WIRING DIAGRAM Each case has its own wiring diagram folded and in its own packet Wiring diagram placement may vary it m...

Страница 5: ...tructural Concepts at 1 800 433 9489 3 Damage Discovered After Uncrating 3rd Party Carrier Contact carrier within 10 days of delivery for their procures retain all packaging If these steps are not taken carrier may refuse your claim Prepaid and Add Contact carrier and follow same procedure as with 3rd party carrier Also contact Structural Concepts at 1 800 433 9489 within 10 days of delivery 4 Sho...

Страница 6: ... C Unlock Casters Slide unit to rear of skid Slide down ramp and off from skid Ramp Various Types Of Case Shipping Brackets 1 Removing Case Shipping Brackets That Are Attached To Skid Remove screws holding Case Shipping Brackets to skid Remove Case Shipping Brackets from Skid See illustrations below Note Shipping Brackets will vary in size shape material and location depending upon case type and m...

Страница 7: ...e case Obstruction or restriction of air can void warranty 6 Front Grille 2 Removing Shipping Screws Plastic glides are mounted to the unit base to assist in sliding the condenser out for access Remove the front grill by removing the screws located in each of the corners Remove the shipping screws located at base of condenser frame Shipping Screws 12 Front of Case Top View Side View ...

Страница 8: ... left hand side of base Replace front grille Supply power will start evaporator coil fans and the compressor motor From front of case raise deck pans and check to see that the coil fan is functioning properly Replace front grille by inserting screws in locations provided Main Power Switch Removable Front Panel Optional Shelf Not on All Cases ...

Страница 9: ...wn in illustration below First time lighting may require a short warm up period for the bulb Slightly dim or a flickering of new bulb is normal If light do not turn on see TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL section in this operating manual 9 3 Temperature Settings The case temperature is set at the factory supply air 25 F for a case temp of 41 F as determined by the case size The t...

Страница 10: ...lf straight up to separate from brackets Remove brackets Note Initially it may be necessary to remove the nylon shipping bracket retainer Pliers will be required to accomplish this task 2 Light Fixtures Light fixture is located on the top header of case Removal of lamp Rotate lamp 1 4 turn so that pins are aligned in slots and remove bulb Installation of lamp Align pins with slot Insert pins into ...

Страница 11: ... the honeycomb to allow it to be pulled out of honeycomb retainer C Pry downward and away from honeycomb retainer Clean honeycomb with warm water and soap solution Submerse if necessary Use brush to dislodge stubborn or sticky residue Dry by using vacuum s blow mode vs suction mode Honeycomb Air Diffuser Installation D Squeeze honeycomb to allow it to fit into honeycomb retainer E Carefully slide ...

Страница 12: ...ssembly or disassembly and servicing is to be accomplished by licensed refrigeration contractors only Plastic Glide Servicing refrigerant is accomplished from the rear of the case Note Condenser unit does not slide to the rear Lift front panel up and off hooks to remove Service connections are located to the left of the compressor See next page for illustrated parts breakdown of condenser unit Pla...

Страница 13: ...Compressor and Electrical Box Overflow Evap Pan Electric Coil and Electrical Box Sight Glass Filter Dryer Condensate Pan Caution Though refrigerant lines are flexible to facilitate front access maintenance do not crimp or kink copper tubing while sliding condenser unit out from under case Slide condenser unit forward approximately 12 to access components Wicking material optional may be part of ho...

Страница 14: ...s well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concepts Technical Service Department See images below for samples of both refrigerated and non refrigerated serial labels Sample Serial Label For Refrigerated Case Sample Serial Label For Non Refrigerated...

Страница 15: ... non abrasive cloth Weekly Wood Laminate and Painted Surfaces Clean with mild soap and water solution and a soft cloth Monthly Under Case Remove rear panel and or front panel Clean under case with vacuum Case Interior Daily Decks Inserts Wipe down and clean with mild soap water soft cloth Daily Shelves Shelves can be cleaned with a warm soap and water solution and soft cloth or paper towel For stu...

Страница 16: ...e pan and overflow electric coil condensate pan Use wet dry vacuum to remove all residue Use clean towel dipped in soap and water solution to wipe down all fans motor refrigeration lines cords knobs sight glass connectors and all other surfaces Wipe dry Slide back under case Replace front panel Qtly Evaporative Wicking Material Optional Wicking material if any on your hot gas loop condensate syste...

Страница 17: ...rews Slide Roll out condensing unit assembly Remove the four 4 screws holding the Clean Sweep rails intact Remove the Clean Sweep rail Wash rails brushes in hot water and mild soap solution If brushes are worn they must be replaced Call Technical Service Department to replace Toll Free number is listed at end of manual Clean Condensing Coil Use air pressure or industrial strength vacuum clean the ...

Страница 18: ...an pan Rinse thoroughly do not submerse in water Quarterly Under Case Cleaning Once refrigeration package is clear of unit vacuum under case to remove all dust and dirt that may collect under case Case Interior Quarterly Tub Coil Drain Fan Blades Motors Brackets Disconnect power from the case before cleaning the Tub Coil Fan Motor and Drain Area Remove Decking Sub Deck and Fan Shroud Use vacuum to...

Страница 19: ...t case rear near main power switch for Type of case If unable to resolve issue of water on floor contact technical service Call toll free number listed at end of manual Excessive Fan Noise Check that the case is aligned level and plumb System is not Operating Check that the utility power is on Check that the MAIN power switch is on Check the circuit breaker box for tripped circuits Digital Control...

Страница 20: ...by product or other décor Note Product displayed on Front Air Grilles will cause case to run warm and will negate warranty Condensing Unit Not Operating Check that the main power switch is turned on Check that case is on and the control display is not blank If blank call toll free number at end of manual Controller may be in defrost mode Compressor cycling on and off is a normal condition Carel Te...

Страница 21: ...ed over condensate pan or floor drain for remote units Check store conditions To prevent condensation in Type 1 environments maximum conditions are to be 55 humidity 75 Fahrenheit For Type 2 environments maximum conditions are to be 60 humidity 80 Fahrenheit See serial label at case rear near main power switch for Type of case Caution Wicking material if any on your particular hot gas loop system ...

Страница 22: ...heck that the MAIN power switch is on Check that fans are plugged in at the fan shroud Check for foreign material obstructing fan performance Check that fan blades freely rotate within fan shrouds Check that power is going to fans Check that fan wiring is connected on terminal blocks Digital Control Display Is Blank Check that the MAIN power switch is on Check the circuit breaker box for tripped c...

Страница 23: ...NGS PRECAUTIONS WIRING PLUGS section in manual for adverse conditions spacing issue parameters Check that condenser coil has been cleaned Check air return grilles for obstructions Check sight glass for flashing and or low charge Check Set Point Temperature it may be adjusted too high Condensing Unit Is Not Operating Check that the power is turned on Determine if temperature controller settings are...

Страница 24: ... timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Set Set aux Prg mute def Prg mute Set Set def Set aux aux def Set Prg mute Oper Manuals PUB Templates Carel Controller Carel Controller IR33 pub This data derived from Carel Material ir33 030220441 rel ...

Страница 25: ...eset reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 User Interface Display 25 ...

Страница 26: ...ator min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 5 Select Celsius C or Fahrenheit F flag C 0 1 26 For Case Specific Defaults See Serial Label Located Near Electrical Access On Your Case For Additional Technical Information Call Structural Concepts Technical Service Dept at 1 800 433 9489 Unit Of Measure Read And...

Страница 27: ...d by SCC as a result of or in connection with any act omission or use of the Goods by Purchaser its employees or customers or any breach of this Agreement by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative and may be exercised from time to time In a proceed...

Отзывы: