- EN -
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at [email protected]. Or visit our website at www.oase-livingwater.com
15
3.2 Unit
configuration
C
Description
1 Container
cover
2
Signal box with level detection device (3) and temperature probe (7)
The signal box is connected to the control system (30, 32)
3
Level detection device
Signals the water level in the filter system
4
Rollers for guiding the filter drum
6
Filter drum with six screen elements
screen elements for coarse dirt down to 80 µm in size (also optionally available with 60 µm)
7 Temperature
probe
monitors the water temperature
8 Air
hose
⅜
in (9 mm)
9
Hel-X 13 biomedia in Moving Bed filter chamber
10
Outlet 4 in (DN 110)
11 Meshed
tube
Prevents the Hel-X biomedia from being flushed out
12
Aerator rod (two provided)
13
Rinsing pump for supplying the rinsing device (24)
14
Dirt outlet DN 75 with slide valve and supplied adapter DN 75 / 3 in.
with slide valve
15
2 × adapters, 2 × 30° inlet bend with union nut for connection of the UVC clarifier Bitron to 1½ in (38 mm) connections
(16)
16
Connection set for connecting filter pumps, 1 × 1½ in ( 38 mm) hose connector, 1 × 2 in ( 50 mm) hose connector, 1 ×
union nut for hose connector, 1 × 40 … 60 mm hose clip, 1 × 90° (2 in) connection bend, 1 × union nut for connection
bend, 1 × cover cap (with 1 × non-return valve, 1 × flat seal 60 mm × 47 mm × 3 mm), 1 × flat seal (2 in)
56 mm × 43 mm × 3 mm
17
2 × 1½ in ( 38 mm) connection, closed with sealing plugs
Optional connection for UVC clarifier Bitron
18
1 × 2 in ( 50 mm) connection for connecting the filter pumps
21
4 in (DN 110) dirt outlet for coarse dirt
22
Drum motor for filter drum
the motor is connected to the control system (30, 31)
23 Dirt
channel
collects the coarse dirt and rinsing water from the screen elements (6)
24 Rinsing
device
sprays water at high pressure onto the screen elements (6) to rinse off the coarse dirt
25
Grease for the drum seal
27 Adapter
from
⅜
in to
⅛
in (9 mm to 4 mm)
28 Tee
29
2 × cable binders for fastening the air hoses to the tee
30
Control system with EGC box
Allows integration with cables into an EGC network.
31
Plug for connecting the drum motor
32
Socket for connecting the signal box
33
Mains connection cable
34
Socket for connecting the capacitor box of the rinsing pump
35 Fuse
holder
Fuse protection of the control system with 5 × 20 mm, T16A, 250 V safety fuse
36
2 × caps, cap nuts for fixing the EGC box when mounting it on the container wall
37
Capacitor box for the rinsing pump
38
Plug for connecting the control system (34)
39
Plug for connecting the rinsing pump
Содержание ProfiClear Premium Compact-M EGC
Страница 2: ...2 A ProfiClear0176...
Страница 3: ...3 B ProfiClear0177 C ProfiClear0172...
Страница 4: ...4 D ProfiClear0112 E BTC0027...
Страница 5: ...5 F G ProfiClear0167 ProfiClear0168 H ProfiClear0169 I ProfiClear0170...
Страница 7: ...7 N BTC0031 O PrifiClear0083 P BTC0025...
Страница 8: ...8 Q ProfiClear0084 R ProfiClear0085 S T BTC0023 BTC0024...
Страница 9: ...9 U ProfiClear0178 s...
Страница 92: ...OASE GmbH www oase livingwater com Tecklenburger Stra e 161 48477 H rstel Germany 72631 02 19...