- EN -
26
Connection
Connecting
How to proceed:
D, E, O
1. Remove the protection cap from EGC-IN.
2. Fit the plug connector of the cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
Integrating the pump in the EGC network
P
The pump can be integrated in an EGC network. The InScenio FM-Master WLAN EGC and all EGC compatible units
are connected with each other via Connection Cable EGC in an EGC network. A terminal resistor has to be fitted to the
EGC-OUT of the last EGC compatible unit in order to terminate the network.
•
The EGC connection cable is available as an accessory in the lengths 2.5 m (47038), 5 m (47039) and 10 m (47040).
•
Ensure the correct connection.
How to proceed:
D, E, O, P
1. Remove the protection cap from EGC-IN.
2. Fit the plug connector of the ECG connection cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT, fit the terminal resistor and secure it with the two screws (max. 2.0 Nm)
or another EGC compatible unit.
– No Connection Cable EGC is connected to EGC-OUT on the last unit in the EGC network. The terminal resistor
has to be fitted to this EGC-OUT so that the EGC network is correctly terminated.
– The terminal resistor is included in the delivery scope of the InScenio FM-Master WLAN EGC.
Commissioning/start-up
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
•
Do not connect the unit to a dimmable power supply.
N O T E
The formation of a small amount of rust on the pump is completely normal in a damp environment.
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length
(Envi-
ronmental Function Control (EFC))
. The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.
Switching on the pump
•
Connect the unit to the power supply.
•
Switch on the pump with Eco Control.
– The pump will start up immediately if it was switched on with the Eco Control beforehand.
Switching off the pump
•
Switch the pump off with Eco Control.
•
Disconnect the unit from the power supply
Содержание AquaMax Eco Titanium 30000
Страница 2: ...2 A B AMX0050 AMX0045 C AMX0029 D E AMX0049 AMX0038...
Страница 3: ...3 F G AMX0055 AMX0056 H AMX0037 I AMX0042...
Страница 4: ...4 J AMX0051 K AMX0040...
Страница 5: ...5 L AMX0052...
Страница 6: ...6 M AMX0043...
Страница 7: ...7 N PLX0004 O FMR0031...
Страница 8: ...8 P AMX0053...
Страница 9: ...9 Q AMX0041...
Страница 25: ...235 AquaMax Eco Titanium 30000 AMX0057 AMX0058...
Страница 26: ...236 AquaMax Eco Titanium 50000 AMX0059 AMX0060...
Страница 27: ...46965 12 16...