- 12 -
1
2
SERVICE
OFF
OFF
AUTOTEST
OFF
ON
PERSONNE PRESENTE
ON
OFF
SEMI-AUTOMATIQUE
ON
ON
AUTOMATIQUE
3
SEQUENCE AUX COMMANDES START
OFF
OUVERTURE. ; SEULEMENT AVEC FCO FERMETURE; EN
FERMETURE, ARRET ET OUVERTURE ( PROG. IMMEUBLE ).
ON
OUVERTURE, STOP, FERMETURE, STOP, OUVERTURE......
4
PRE CLIGNOTEMENT
OFF
EXCLU
ON
INCLU ( 2.5" AVANT CHAQUE PHASE DE MOUVEMENT )
5
CELLULE PHOTO-ELECTRIQUE
OFF
INTERVIENT UNIQUEMENT EN FERMETURE EN ARRETANT
ET EN OUVRANT JUSQU'A FCO.
ON
AUSSI BIEN EN OUVERTURE QU'EN FERMETURE, ARRETE
ET, UNIQUEMENT SI LIBEREE, OUVRE A NOUVEAU
6
REVERSER
OFF
EXCLU
ON
INCLU
7
INVERSION DU SENS DE MARCHE
OFF
MARCHE DIRECTE
ON
MARCHE INVERSEE
8
NON UTILISE
OFF
MAINTENIR NECESSAIREMENT EN OFF
APPAREILLAGE ELECTRONIQUE ASX03I
MICROPROCESSEUR
GROUPE
FUSIBLES
GROUPE
RELAIS
CONNECTEUR
REVERSER
TRIMMERS
CONNECTEUR
RADIO
TOUCHE
RESET
F1
TRS
160mA
F2
SLR
250mA
F3
ENG
4A
F4
24V
500mA
LED LGT
TRANSFORMATEUR
F3
F1
F2
F4
MICRO INTERR.
DE PROGRAMM.
BORNES
SORTABLES
DIP
FONCTION
PROGRAMMES ET FONCTIONS
ATTENTION
TRIMMER REGL. DU
TEMPS DE SERVICE
( 2 ÷ 80" )
DIP-SWITCH DE
PROGRAMMATION
LED LGT
FCA
FIN DE COURSE OUVERTURE
FCC
FIN DE COURSE FERMETURE
LUX
CELLULE PHOTOELECTRIQUE
STP
POUSSOIR STOP
RUN
POUSSOIR START
PAR
POUSSOIR START PIETON
REV
REVERSER
LED CONTROLE
COMMANDES ET CONTROLES
LEDS DE CONTROLE
0-1-2
LIGNE MONOPHASÉE 230 Vca
11-12
CLIGNOTANT
13-23
CONTACT AUXILIAIRE
18-19
24 Vca PHOTOCELLULE
14-15
CONTACT AUXILIAIRE 24Vca MAXI.
300mA
7
CONTACT NF STOP
8
COMMUN GND BOUTONS-POUSS.
9
CONTACT NO START
43
CONTACT NO START PIETON
8-10
LAMPE-TEMOIN 24Vca - 3W
Après une modification de configuration des
dip-switches, mémoriser la modification
par
RESET
.
TRIMMER REGL. DU
TEMPS DE PAUSE
( 2 ÷ 120" )