Keypad

The large membrane keypad makes the instrument easy to use. Each button, 
when pressed, has a corresponding graphic indicator on the LCD.

ON

• Switches the meter on
• Use with other function keys to access advanced options

OFF

•  Switches the meter off

C/F

•  Toggles display between °F and °C

Mn/Mx

•  Displays the minimum and maximum measured values
•  Increases/decreases the temperature offset value
•  Increases/decreases the alarm setting values 
•  Changes default display to °C or °F
•  Switches between automatic shutoff and non-sleep modes

RST

•  Resets the minimum and maximum memory values
•  Erases alarm settings
•  Discontinues the calibration mode
•  Switches from alarm check or alarm set to measuring mode

HOLD  

•  Freezes the measured reading. To activate, press HOLD while in 

measurement mode. To release, press HOLD again.

NEXT

•  Selects the next digit for alarm setting
•  Displays the next alarm setting value
•  Selects the next digit for calibration

PRG

•  Switches from measuring 

(program)

to alarm check mode

•  Switches from alarm 

check to alarm set mode

•  Saves settings and 

calibration data

•  Switches to calibration 

mode when pressed 
with “ON”

5

4

2. Display and Keypad Functions

Display

The LCD has a primary and secondary display. 

• The primary display shows the measured humidity (or dewpoint) reading. 
• The secondary display shows the temperature of the reading in °C. 

The display also shows error messages, keypad functions and program functions.

F

C

LOTEMP

HITEMP
LO%RH

HI%RH

MIN

MAX

HOLD

td

%RH

2.1

2.2

Primary
display

Secondary display

Relative
Humidity
indicator

Low
Temperature
alarm indicator

High
Temperature
alarm indicator

Low 
Humidity 
alarm 
indicator

High
Humidity
alarm 
indicator

MINimum
indicator

HOLD
indicator

MAXimum
indicator

Dewpoint
indicator
(WD-35612-10 only)

Degrees
Fahrenheit 
indicator

Degrees
Celsius 
indicator

Mn/Mx

ON

RST

OFF

HOLD

C / F

NEXT

PRG

Содержание 35612-series

Страница 1: ...mer misuse Out of warranty products will be repaired on a charge basis 13 Return of items Authorization must be obtained from our Customer Service Department before returning items for any reason When...

Страница 2: ...mode 17 7 2 Min Max memory mode 18 7 3 Hold mode 19 7 4 C F mode 19 8 Advanced Operations 20 9 Troubleshooting Error Messages 21 10 Specifications 22 11 Accessories 23 12 Warranty 24 13 Return of Item...

Страница 3: ...e next digit for alarm setting Displays the next alarm setting value Selects the next digit for calibration PRG Switches from measuring program to alarm check mode Switches from alarm check to alarm s...

Страница 4: ...The probe cable has a notched 6 pin connector to attach the probe to the meter NOTE Do not substitute other probes For a replacement probe see the Accessories section page 23 NOTE Keep connector dry...

Страница 5: ...new temperature offset value Tnew by adding the results in steps a and b and subtracting the results in c Tnew To Tm Ts Tnew __________ Other Connections Three other connections are available Serial...

Страница 6: ...es not meet your accuracy requirements If the values are only slightly different and you do not require the highest possible accuracy then calibration is not necessary Two point relative humidity cali...

Страница 7: ...nt Measuring dewpoint model WD 35612 10 only I J Fast humidity calibration Follow the directions below to calibrate humidity more quickly Please note that using this calibration method may result in a...

Страница 8: ...re value in C press Mn Mx to place or remove a sign in front of the old value ii Press NEXT if necessary one or more times until the digit you need to change is flashing See figure iii Press Mn Mx unt...

Страница 9: ...s 2 through 4 Otherwise press RST to return to the measurement mode To cancel an alarm setting 1 In the alarm set mode select the alarm set point you wish to cancel i In the measurement mode press PRG...

Страница 10: ...ays SA for saved The screen then displays RH See figure 6 Press OFF When the meter is turned on again it will default to the new temperature measuring mode X X Min Max memory mode Press Mn Mx to displ...

Страница 11: ...Indicates Cause Solution Readout flashing OP Beeping Probe incorrectly Improper setup Check probe connected or faulty wire connection 0 0 Probe is Rough handling or Replace the 99 9 damaged defective...

Страница 12: ...Adapter 110 VAC WD 35615 08 AC Adapter 220 VAC 10 Specifications Mode Relative Dew Point Temperature Humidity WD 35612 10 only Range 0 to 99 9 RH 51 0 to 49 0 C 0 to 50 0 C 60 0 to 120 0 F 32 0 to 12...

Отзывы: