Oakton 35612-series Скачать руководство пользователя страница 2

Table of Contents

1. Introduction

................................................................................................................3

1.1. Packing List ................................................................................................................3

2. Display and keypad functions

......................................................................4-5

2.1 Display ..........................................................................................................................4
2.2 Keypad..........................................................................................................................5

3. Meter preparation

................................................................................................6-8

3.1 Inserting the batteries ................................................................................................6
3.2 Connecting the probe to the meter ..........................................................................7
3.3 Connecting the optional AC adapter ......................................................................8
3.4 Other connections ......................................................................................................8

4. Calibration

................................................................................................................9-12

4.1 Temperature calibration..............................................................................................9
4.2 Relative Humidity calibration............................................................................10-12

• Before humidity calibration..................................................................................10
• Automatic humidity calibration ....................................................................10-11
• Fast humidity calibration......................................................................................12

5. Measurement

............................................................................................................13

• Measuring humidity ............................................................................................13
• Measuring dewpoint (model WD-35612-10 only) ..........................................13

6. Alarms

......................................................................................................................14-16

6.1 Viewing alarm set points..........................................................................................14
6.2 Setting alarm set points ............................................................................................15

• To cancel an alarm setting ....................................................................................16
• To cancel all four alarm settings at once ............................................................16

7. Other meter functions

....................................................................................17-19

7.1  Automatic shut-off mode ........................................................................................17
7.2  Min/Max memory mode ........................................................................................18
7.3  Hold mode ................................................................................................................19
7.4  °C/°F mode ..............................................................................................................19

8.  Advanced Operations

..........................................................................................20

9.  Troubleshooting/Error Messages

................................................................21

10. Specifications

..........................................................................................................22

11. Accessories

................................................................................................................23

12. Warranty

....................................................................................................................24

13. Return of Items

......................................................................................................24

3

1. Introduction

Thank you for selecting the Oakton

®

WD-35612-series thermohygrometer kit. 

This kit includes a portable, microprocessor-based relative humidity and tempera-
ture hygrometer that measures relative humidity (RH) from 0 to 99.9% RH and 
temperature from 0.0° to 199.9°F (–18° to 93°C). Model WD-35612-10 also reads 
dewpoint. Use these meters for ambient air and environmental applications. 

Caution:  

Do not submerge the probe in a liquid or powder or else damage to the
probe may occur. Probe is for ambient air use only.

Packing List

The following items should be in your shipping box:

•  Meter
•  Probe
•  Hard carrying case
•  Two (2) calibration salt bottles
•  Four (4) batteries, type AAA
•  Instruction manual

1.1

Thermohygrometer

Mn/Mx

ON

RST

OFF

HOLD

C / F

NEXT

PRG

F

%RH

Содержание 35612-series

Страница 1: ...mer misuse Out of warranty products will be repaired on a charge basis 13 Return of items Authorization must be obtained from our Customer Service Department before returning items for any reason When...

Страница 2: ...mode 17 7 2 Min Max memory mode 18 7 3 Hold mode 19 7 4 C F mode 19 8 Advanced Operations 20 9 Troubleshooting Error Messages 21 10 Specifications 22 11 Accessories 23 12 Warranty 24 13 Return of Item...

Страница 3: ...e next digit for alarm setting Displays the next alarm setting value Selects the next digit for calibration PRG Switches from measuring program to alarm check mode Switches from alarm check to alarm s...

Страница 4: ...The probe cable has a notched 6 pin connector to attach the probe to the meter NOTE Do not substitute other probes For a replacement probe see the Accessories section page 23 NOTE Keep connector dry...

Страница 5: ...new temperature offset value Tnew by adding the results in steps a and b and subtracting the results in c Tnew To Tm Ts Tnew __________ Other Connections Three other connections are available Serial...

Страница 6: ...es not meet your accuracy requirements If the values are only slightly different and you do not require the highest possible accuracy then calibration is not necessary Two point relative humidity cali...

Страница 7: ...nt Measuring dewpoint model WD 35612 10 only I J Fast humidity calibration Follow the directions below to calibrate humidity more quickly Please note that using this calibration method may result in a...

Страница 8: ...re value in C press Mn Mx to place or remove a sign in front of the old value ii Press NEXT if necessary one or more times until the digit you need to change is flashing See figure iii Press Mn Mx unt...

Страница 9: ...s 2 through 4 Otherwise press RST to return to the measurement mode To cancel an alarm setting 1 In the alarm set mode select the alarm set point you wish to cancel i In the measurement mode press PRG...

Страница 10: ...ays SA for saved The screen then displays RH See figure 6 Press OFF When the meter is turned on again it will default to the new temperature measuring mode X X Min Max memory mode Press Mn Mx to displ...

Страница 11: ...Indicates Cause Solution Readout flashing OP Beeping Probe incorrectly Improper setup Check probe connected or faulty wire connection 0 0 Probe is Rough handling or Replace the 99 9 damaged defective...

Страница 12: ...Adapter 110 VAC WD 35615 08 AC Adapter 220 VAC 10 Specifications Mode Relative Dew Point Temperature Humidity WD 35612 10 only Range 0 to 99 9 RH 51 0 to 49 0 C 0 to 50 0 C 60 0 to 120 0 F 32 0 to 12...