INSTALLATION
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12” ( 0.5 cm) of
the ceiling and one within 12” ( 0.5 cm) of
the fl oor. Connect these items directly to the
outdoors or spaces open to the outdoors.
These spaces include attics and crawl
spaces. Follow the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, Section 5.3, Air for
Combustion and Ventilation for required size
of ventilation grills or ducts.
IMPORTANT
: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
NOTICE: This fi replace is intended
for use as supplemental heat.
Use this fi replace along with your
primary heating system. Do not
install this fi replace as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using fi replace. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this fi replace
as your primary heat source.
IMPORTANT: Vent-free fireplaces add mois-
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for
Combustion and Ventilation, page 6.
Note: Your fireplace is designed to be
used in zero clearance installations. Wall
or framing material can be placed directly
against any exterior surface on the rear,
sides or top of your fireplace, except where
standoff spacers are integrally attached.
If standoff spacers are attached to your
fireplace, these spacers can be placed
directly against wall or framing materials.
WARNING: Never install in a
bedroom or bathroom. Any heating
product with a Btu/Hr rating over
10,000 cannot be used in a bedroom.
WARNING: A qualified ser-
vice person must install fireplace.
Follow all local codes.
WARNING: Never install the
fireplace
• in a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 36”
(91.5 cm) from the front, top
or sides of the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
AIR FOR COMBUSTION AND VENTILATION
Continued
CAUTION: This fi replace cre-
ates warm air currents. These cur-
rents move heat to wall surfaces
next to fi replace. Installing fi replace
next to vinyl or cloth wall coverings
or operating fi replace where impu-
rities (such as, but not limited to,
tobacco smoke, aromatic candles,
cleaning fl uids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.