Changing from Propane/LP Gas to
Operation on Natural Gas
Carefully remove logs. Loosen the 3 screws
1.
on the top of the fi rebox back. (See Figure
7) and remove the hood top and fi re brick
top from fi rebox. Remove the 2 screws on
the top of the fi re brick left and right. Then
remove fi re bricks from the fi rebox. (See
Figure 8)
INSTALLATION
Continued
Figure 8 - Removing Floor Assembly
Figure 9 - Changing Gas Type
6. Remove set screw from selector valve
linkage (see Figure 10, page 12).
7. Slightly press selector plate and rotate
linkage clockwise until it stops.
8. Reinstall set screw.
9. Mark on rating label natural gas.
Note: Slot in linkage will indicate the type
of gas selected. Blue color code on linkage
decal will indicate correct setting for natural
gas.
10. Place fl oor assembly inside fi rebox.
Connect to gas supply and check for leaks
(see page 13). Replace screws securing
fl oor assembly to fi rebox.
11. Replace fi re bricks into fi rebox and secure
the screws. Replace logs into fi rebox.
Flex Line
Regulator
Figure 9 - 1
Figure 9 - 2
Figure 9 - 3
Figure 9 - 4
Cap
LP to NG Setting
NG to LP Setting
Figure 9 - 5
Figure 9 - 6
Figure 9 - 7
Figure 9- 8
Cap
White Plastic
Screw
Cap
White Plastic
Screw
Flex Line
Floor Assembly
6 Screws
11
Fire bricks
2 Screws
2. Remove 6 screws securing fl oor assembly
to fi rebox (see Figure 8).
3. Carefully remove fl oor assembly from
inside fi rebox.Carefully turn fl oor assembly
over so com- ponents underneath fl oor are
accessible from the rear. Remove the cap
by hand from the regulator and now the
white plastic screw is in the LP position.
(see Figure 9-1).
4. Remove the white plastic screw by hand
from the cap. (See Figure 9-2)
5. Turn it over (See Figure 9-3) and reinstall it
on the cap (See Figure 9-4). Make sure the
white plastic screw is installed on the cap
tightly. Reinstall the cap to the regulator.
Figure 7 - Removing Fire Bricks
3 Screws
Содержание VFF23NLM