CLEANING AND MAINTENANCE
BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these
holes clear of dust, dirt, lint and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will create
soot. We recommend that you clean the unit
every three months during operation and
have fireplace inspected yearly by a qualified
service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please
follow the directions on the can. If you don’t
follow directions on the can, you could dam-
age the pilot assembly.
1. Shut off unit including pilot. Allow unit to
cool for at least 30 minutes.
2. Inspect burner, pilot and primary air inlet
holes on injector holder for dust and dirt
(see Figure 28).
3. Blow air through the ports/slots and holes
in the burner.
4. Check injector holder located at the end
of burner tube again. Remove any large
particles of dust, dirt, lint or pet hair with
a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now
been pushed into the burner repeat steps
3 and 4.
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
hole about 2” from where the pilot flame comes
out of the pilot assembly (see Figure 29). With
the unit off, lightly blow air through the air inlet
hole. You may blow through a drinking straw
if compressed air is not available.
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and cir-
culating air passageways of
fireplace clean. Inspect these
areas of fireplace before each
use. Have fireplace inspected
yearly by a qualified service
person. Fireplace may need
more frequent cleaning due to
excessive lint from carpeting,
pet hair, bedding material, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
Figure 28 - Injector Holder On Outlet
Burner Tube
Figure 29 - Injector Holder On Outlet
Burner Tube
LOG SET
• If you remove one-piece log set for cleaning,
refer to page 18, for placement instructions.
• Replace log set if broken or chipped (dime-
sized or larger).
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to
clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.
20
Burner
Tube
Injector
Holder
Primary Air
inlet Holes
Содержание VFF23NLM