Propane/LP Gas Setting
Figure 10 - Gas Selector Valve Plate
Natural Gas Setting
INSTALLATION
Continued
Changing from Natural Gas to
Operation on Propane/LP Gas (for
Previously Installed Log Sets)
Carefully remove logs. Loosen the 3 screws
1.
on the top of the fi rebox back. (See Figure
7) and remove the hood top and fi re brick
top from fi rebox. Remove the 2 screws on
the top of the fi re brick left and right. Then
remove fi re bricks from the fi rebox. (See
Figure 8)
Remove the screws securing fl oor assembly
2.
to fi rebox (see Figure 8, page 11). Carefully
remove fl oor assembly from inside fi rebox.
Carefully turn fl oor assembly over so
3.
components underneath fl oor are acces-
sible from the rear. Remove the cap by
hand from the regulator and now the white
plastic screw is in the NG position. (see
Figure 9-5).
Remove the white plastic screw by hand
4.
from the cap. (See Figure 9-6)
5. Turn it over (See Figure 9-7) and reinstall it
on the cap (See Figure 9-8). Make sure the
white plastic screw is installed on the cap
tightly. Reinstall the cap to the regulator.
6. Remove set screw from selector valve
linkage (see Figure 10).
7. Slightly press selector plate and rotate
linkage counterclockwise until it stops.
8. Reinstall set screw.
9. Mark on rating label propane/LP gas.
Note: Slot in linkage will indicate the type
of gas selected. Red color code on linkage
decal will indicate correct setting for
propane/LP gas.
10. Place fl oor assembly inside fi rebox.
Connect to gas supply and check for leaks
(see Connecting to Gas Supply, page 16).
Replace screws securing fl oor assembly to
fi rebox.
11. Replace fi re bricks into fi rebox and secure
the screws. Replace logs into fi rebox.